Parameter setting
Radio actuator KNX RF MSG-DST
Version: 27.06.2018 • Technical changes and errors excepted.
the end positions with help from the greater current on the drive output. For this, regu-
lar reference movements (see below) should be set.
If a dead time is observed while starting the curtain, then this can be entered manually
at this point or calculated automatically. Obey the manufacturer's instructions for the
curtain.
Runtime zero position and step setting of slats:
(only for shutters)
The zero position is the starting position of 0% as the initial point of movement posi-
tions. Adjusting the zero position runtime, multiple shades of a façade can be optically
synchronised.
Step time x step number determines the turning time of the slats.
Use an automatic runtime measurement
no • yes
Use an automatic runtime measurement
no
Runtime DOWN in sec
(shutter, blinds)
Runtime OFF in sec
(awning)
Runtime UP in sec
(window)
1 … 320; 60
Runtime OPEN in sec
(shutter, blinds)
Runtime ON in sec
(awning)
Runtime CLOSE in sec
(window)
1 … 320; 65
Use dead times
• no
• yes, enter by hand
• yes, calculate automatically
during the position travel from closed
position in 10 ms
(only for manual input)
0 ... 600
for position movement from all other
positions in 10 ms
(only for manual input)
0 ... 600
for slat movement from closed
position in 10 ms
(only for manual input)
0 ... 600
for movement with change of direction
in 10 ms
(only for manual input)
0 ... 600
for slat movement from all other
positions in 10 ms
(only for manual input)
0 ... 600
Runtime zero position in 0.1 sec
0 … 255