MC Connection Diagram
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
Normally Closed
User can change
Fuse
Relay
Relay
Open
Close Stop
Master
Control
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor 2
Motor 2
AC Supply
AC Supply
B
Battery -
Open Limit
Common
Motor 1
Close Limit
Motor 1
Open Limit
Motor 2
Close Limit
Motor 2
Push Button
Open
Close
Stop
Common
PED Access
Photo Beam
+ 12 VDC
- 12 VDC
Output 1 C
Output 1 NO
Output 2 C
Output 2 NC
Output 2 NO
+
-
Power
Output
LED
AC Supply :
24/12 Volts AC
Model :
MCv1
Designed by
ELSEMA
IN AUSTRALIA
Normally Closed
User can change
AC Supply
DNS
Day and Night Sensor
ELSEMA
Normally Open
User can change
Eclipse
operating
system
Powered By
Receiver
Program 2
Program 1
Antenna 1
Shield
Antenna 2
Output Rated
at 250mA
Built-in
Receiver
DNS Connection : On the top right corner of the control card is a connection for Day and Night Sensor
(DNS). This sensor is available from Elsema and is used to detect daylight. This feature can be used to
Auto Close the gate at night, turn on the courtesy light or lights on your gates during the night and many
more features which require a day and night detection.