The control card has two relay outputs, Output 1 and Output 2. The user can change the function of these
outputs to lock / brake, courtesy light, service call, strobe (Warning) light, locking actuator or gate open
(gate not fully closed) indicator.
Output 1 is a voltage free relay output with common and normally open contacts. Factory default is lock /
brake release function.
Output 2 is a voltage free relay output with common, normally open and normally closed contacts. Factory
default is courtesy light function.
Menu No.
Relay Output
Function
Factory
Default
Adjustable
5.1
Relay Output 1
Lock / Brake
Lock / Brake
------------------------------------
Courtesy Light
------------------------------------
Service Call
------------------------------------
Strobe (Warning) Light
------------------------------------
Locking Actuator
------------------------------------
Gate open
5.2
Relay Output 2
Courtesy Light
Lock / Brake
------------------------------------
Courtesy Light
------------------------------------
Service Call
------------------------------------
Strobe (Warning) Light
------------------------------------
Gate Open
5.3
Exit
Menu 5 – Relay Output Functions
16
Double Gate & Door Controller
with Eclipse
®
Operating System (EOS)