Menu 6.1 – Lock / Brake
The relay output in the lock / brake mode can be configured in different ways.
Menu No.
Lock / Brake Modes
Factory
Default
Adjustable
6.1.1
Open Lock / Brake Activation
2 seconds
1 – 30 seconds
or hold
6.1.2
Close Lock / Brake Activation
Off
1 – 30 seconds
or hold
6.1.3
Open Pre-Lock / Brake Activation
Off
1 – 30 seconds
6.1.4
Close Pre-Lock / Brake Activation
Off
1 – 30 seconds
6.1.5
Drop Lock
Off
Off / On
6.1.6
Exit
6.1.1 Open Lock / Brake Activation
This sets the time the output is activated. Factory
default is 2 seconds. Setting it to Hold means the
output is activated for the total travel time in the
open direction.
6.1.2 Close Lock / Brake Activation
This sets the time the output is activated. Factory
default is off. Setting it to Hold means the output
is activated for the total travel time in the close
direction.
6.1.3 Open Pre-Lock / Brake Activation
This sets the time the output is activated before
the motor starts in the open direction. Factory
default is Off.
6.1.4 Close Pre-Lock / Brake Activation
This sets the time the output is activated before
the motor starts in the close direction. Factory
default is Off.
6.1.5 Drop Lock
This mode should be enabled when a drop lock is
used. It will hold the lock if the gates are stopped
in the middle of it’s travel.
Menu 6 – Relay Output Modes
19