Menu 6.2 – Courtesy Light
The relay output in the courtesy mode can be adjusted from 2 seconds to 18 hours. This sets the time
the courtesy light is activated after the gate has stopped. Factory default is 1 minute.
Menu No.
Courtesy Light Mode
Factory
Default
Adjustable
6.2.1
Courtesy Light Activation
1 minute
2 seconds to
18 hours
6.2.2
Courtesy Light at Night Only with DNS
(Day and Night Sensor) Connected
Off
Off / On
6.2.3
Exit
Menu 6.3 – Strobe (Warning) Light
The relay output in the strobe (Warning) light stays “on” while the gate is moving. This output can also
be configured to come “on” before the gate starts to move.
Menu No.
Strobe (Warning) Light Mode
Factory
Default
Adjustable
6.3.1
Pre-Open Strobe (Warning)
Light Activation
Off
1 – 30 seconds
6.3.2
Pre-Close Strobe (Warning)
Light Activation
Off
1 – 30 seconds
6.3.3
Exit
6.3.1 Pre-Open Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the open direction. Factory
default is Off.
6.3.2 Pre-Close Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the close direction. Factory
default is Off.