Leaf delay is used when one gate leaf will close in an overlapping position to the first closed leaf. This
leaf delay may also be necessary for special add-on locking pins. The control card has separate leaf
delay for the open and close directions.
When the control card is used with a single motor the leaf delay mode is disabled.
Menu No.
Leaf Delay
Factory
Default
Adjustable
8.1
Open Leaf Delay
3 seconds
Off - 25 seconds
8.2
Close Leaf Delay
3 seconds
Off - 25 seconds
8.3
Close Leaf Delay on Mid Stop
Off
Off / On
8.4
Exit
8.1 Open Leaf Delay
Motor 1 will start opening first. After leaf delay time has expired motor 2 will start opening.
8.2 Close Leaf Delay
Motor 2 will start closing first. After leaf delay time has expired motor 1 will start closing.
8.3 Close Leaf Delay on Mid Stop
By default motor 1 will always have delay when closing even if the gate is not fully open. When disabled
both motor 1 and motor 2 will start closing at the same time only when not fully open.
Menu 8 – Leaf Delay
7.6 & 7.7 Press and Hold for Open and Close Inputs
If this feature is ON the user must continuously press the open or close input for the gate to operate.
7.8 Window or Louvre Mode
This mode optimises the control card for operating automated windows or louvres.
7.9 Wind Loading
Enable this mode for gates installed in High Wind area.
7.10 & 7.11 Press and Hold for Remote Channel 1 (Open) and Channel 2 (Close)
The remote channel 1 & 2 buttons will need to be programmed to receiver channel 1 & 2. The user must
continuously press the remote button for the gate to open or close. The gates will stop as soon as the
buttons are released.
23