background image

   

 

- 27 - 

 

 

The general operations are as 

follows:

 

 

 

▲▼

◄►

 

Press these buttons to select the items. 

 

 

ESC

 

Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press 

ENTER 

to 

exit and save, 

ESC 

to exit without saving. 

The following 

is a brief description for each item and its specific operations: 

 

 

Net Type – Static IP, PPPoE, or DHCP. DHCP can only be used for intranet (LAN) access, while Static IP and PPPoE can be 
used for both internet & intranet access. Press 

+/-

 buttons to change the Net Type. 

 

 

 

IP Address – Ethernet IP address for the system. To get the static IP address, please contact your local ISP (Internet Service 
Provider). Please follow the Text Input method described in 

Section 4.1

 to modify these items. 

 

 

Net Mask – Net Mask for the IP address. Please follow the Text Input method described in 

Section 4.1

 to modify these items. 

 

 

Gateway – Gateway IP address for the system. Please follow the Text Input method described in 

Section 4.1

 to modify these 

items. 

 

 

DNS – DNS (Domain Name Server) IP address for the system. Please follow the Text Input method described in 

Section 4.1

 to 

modify these items. 

 

 

Username – PPPoE username for the system if PPPoE is used. Please follow the Text Input method described in 

Section 4.1

 

to modify this item. 

 

 

Password – PPPoE password for the system if PPPoE is used. Please follow the Text Input method described in 

Section 4.1

 to 

modify this item. 

 

 

DDNS Type – Dynamic, Static, or Custom DDNS (Dynamic Domain Name Server) type.    Please contact your local DDNS 
Service Provider to get the DDNS URL, username, and password. Press 

+/-

 buttons to change this item. 

 

 

URL – the URL (Uniform Resource Locators) for the system if PPPoE is used. Please follow the Text Input method described 
in 

Section 4.1

 to modify this item. 

 

 

DDNS  Username  –  DDNS  username  for  the  system  if  PPPoE  is  used.  Please  follow  the  Text  Input  method  described  in 

Section 4.1

 to modify this item. 

 

 

DDNS  Password  –  DDNS  password  for  the  system  if  PPPoE  is  used.  Please  follow  the  Text  Input  method  described  in

 

Section 4.1

 to modify this item. 

 

 

E-mail – press 

ENTER

 to call up E-mail Setup. Please refer to 

Section 6.10.1 

for the details. 

 

 

Adv. – press 

ENTER

 to call up Advanced Network Setup. Please refer to 

Section 6.10.2

 for the details.

 

 

6.10.1 E-mail Setup 

 

In Network Setup, press 

ENTER

 to call up E-mail Setup as shown when the highlighted option is E-mail

 

 

 

The E-mail  Setup allows the administrator to set e-mail related parameters. When an event occurs and E-mail is enabled for the 
corresponding action, an e-mail will be sent based on the parameters set here. 

 

 

 

 

 

 

 

   

 

- 28 - 

 

 

The general operations are as 

follows

 

 

▲▼

 

Press these buttons to select the items. 

 

 

ESC

 

Press this button to escape from this screen, and return to Network Setup display. If the Save dialog is shown, press 

ENTER 

to exit and save, 

ESC 

to exit without saving. 

 

The following

 is a brief description for each item and its specific operations: 

 

 

SMTP Server – SMTP mail server name. Please follow the Text Input method described in 

Section 4.1

 to modify this item. 

 

 

Authentication – whether the SMTP mail server requires authentication. Press 

ENTER

 

or 

+/-

 

to check/uncheck this item. 

 

 

Username  –  username  if  the  SMTP  mail  server  requires  authentication.  Please  follow  the  Text  Input  method  described  in 

Section 4.1

 to modify this item. 

 

 

Password  –  password  if  the  SMTP  mail  server  requires  authentication.  Please  follow  the  Text  Input  method  described  in

 

Section 4.1

 to modify this item. 

 

 

Mail From – the e-mail address of this DVR unit, i.e. the sender of the e-mails originated from the triggered events. Please 
follow the Text Input method described in 

Section 4.1

 to modify this item. 

 

 

Mail To #1-5 – the receivers’ e-mail addresses. The system can send the e-mails originated from the triggered events to up to 5 
different receivers. Please follow the Text Input method described in 

Section 4.1

 to modify these items. 

 

 

Attachment – attached picture for the e-mail sent. The value could be (N/A, Original picture, QCIF picture). Press 

+/-

 buttons 

to change this item.

 

 

6.10.2 Advanced Network Setup 

 

In Network Setup, press 

ENTER

 to call up Advanced Network Setup as shown when the highlighted option is Adv.

 

 

 

 

 

 

The  Advanced  Network  Setup  allows  the  administrator  to  set  advanced  network  parameters.  If  the  user  is  not  familiar  with 

network administration, please DO NOT modify the items in this dialog. 

 

The general operations are as 

follows

 

 

▲▼

 

Press these buttons to select the items. 

 

 

ESC

 

Press this button to escape from this screen, and return to Network Setup display. If the Save dialog is shown, press 

ENTER 

to exit and save, 

ESC 

to exit without saving. 

 

The following

 is a brief description for each item and its specific operations: 

 

 

Control Port – the control port for remote access. The default value is 

67

. Please follow the Text Input method described in 

Section 4.1 

to modify this item. 

 

 

 

Data Port – the data port for remote access. The default value is 

68

. Please follow the Text Input method described in 

Section 

4.1 

to modify this item. 

 

 

HTTP Port  –  the  HTTP  (web  page)  port  for  remote  access.  The  default  value  is 

80

.  Please  follow  the  Text  Input  method 

described in 

Section 4.1 

to modify this item. 

 

 

WAP  Picture  qulity  (if  this  machine  support  cellular  phone  long  range  interview)Please  press+/-  The  key  changes  initial 
value. 

 
Note: If the Control Port or Data Port is not available or accessible during remote access, the system will reset the ports to 

their default values, i.e. 67/68. 

Содержание DVR154S

Страница 1: ...Performance and lifetime of hard disk drives are easily affected by heat used at high temperature It is recommended to use this appliance at temperature within 20o C 30o C 68o F 86o F Handle the hard...

Страница 2: ...combination of a hard disk recorder a video multiplexer and a web server To achieve the highest inter connectivity and inter operability this series of digital video audio recorders are all based on i...

Страница 3: ......

Страница 4: ......

Страница 5: ...selection 6 If you make a mistake press BS to remove the character to the left of the cursor or press DEL to delete the character at the current cursor position 7 In text editing mode internal code b...

Страница 6: ......

Страница 7: ...D device and then press ENTER to command the system to connect with it If the device is already connected eg R W Read write as shown in Current Status please press ENTER to command the system software...

Страница 8: ...Menu display and return to Menu display If the user wants to reset all the settings to factory default values he she may press to change the highlighted option to Factory Defaults and then press ENTER...

Страница 9: ...0 CIF 60 Half D1 30 Full D1 PAL 100 CIF 50 Half D1 25 Full D1 or the system will lower the actual rate automatically at recording Normal Record IPS the normal record IPS for this camera This camera wi...

Страница 10: ...e the sensitivity from 10 1 for the motion detection of this camera CALL Press this button to increase the sensitivity from 1 10 for the motion detection of this camera SEARCH Press this button to tes...

Страница 11: ...o change the camera for the current page Press these buttons to change the current page for this SEQ Display Type ESC Press this button to escape from Display Page Setup and return to SEQ Display Setu...

Страница 12: ...e formatting the HDD The general operations are as follows MODE Format Press this button to format the HDD A confirmation dialog will be shown on the screen press ENTER to confirm or ESC to 24 cancel...

Страница 13: ...format used for the system time displayed on the lower left corner of the main screen Press buttons to select the desired format Language press buttons to select the language for the system The langu...

Страница 14: ...follows Press these buttons to select the items ESC Press this button to escape from this screen and return to Network Setup display If the Save dialog is shown press ENTER to exit and save ESC to exi...

Страница 15: ...ch Playback Archive Administrator Supervisor There are three ways to search the recorded video audio for playback a Search by time b Search by event c Search archived files In split window display pre...

Страница 16: ...is a brief description for each item and its specific operations Backup Device press ENTER to call up Backup Device dialog if there s no Backup device connected Disk Storage to select the disk storag...

Страница 17: ...this unit through web browser please make sure the followings For most PCs only step 3 6 is needed 1 This unit is connected to the network correctly and the configurations are all setup correctly Plea...

Страница 18: ...vent logs Click on Refresh Up or Down to update the event logs Click on the desired event log to highlight and select it Click on the OK button to search the recorded video audio for the highlighted e...

Страница 19: ...hen double click on Setup exe in the CD to install and Utilities Setup exe to install the utility programs Please follow the instructions on the screen to install the software in the default directory...

Страница 20: ...face reference When you make use of the mouse operation the DVR please move the cursor to screen below you will see the icons of mouse function displayed pressing the diagram mark to hint an operation...

Страница 21: ...n setup via keypad I R remote control Remote Setup upload via Windows application software 42 Multi lingual Yes Reliability System recovery Auto power on after power loss recovery Timer Built in real...

Страница 22: ...88 176 265 529 6 18 4 101 201 302 604 5 14 0 132 265 397 794 4 11 3 164 328 492 983 3 7 7 241 481 722 1443 2 5 6 331 661 992 1984 1 3 6 514 1029 1543 3086 720x240 9 16 1 58 115 230 345 690 Half D1 8 1...

Страница 23: ...889 1778 2778 5556 2 2 2 292 585 1170 2339 3655 7310 1 1 4 463 926 1852 3704 5787 11574 Average Picture Size is estimated based on typical camera scene and averaged by H 264 I P P frames NOTE Above s...

Отзывы: