- 19 -
Press this button to escape from this screen, and return to Camera Setup display. If the Save dialog is shown, press
ENTER
to
exit and save,
ESC
to exit without saving.
The following
is a brief description for each item and its specific operations:
Duration – response duration to define at most how long (in seconds) the Alarm Out relay and the Buzzer will keep being
triggered after motion is detected for this camera. However, the Alarm Out relay and the Buzzer will be reset immediately
once the camera returns to normal. Press
+/-
buttons to adjust the value (3-60 seconds, discrete).
Goto Preset – to define the preset position to go to if motion is detected and this camera is a PTZ camera. For more details
about preset locations, please refer to
Chapter 7 PTZ Control
.
Pre-record – to define how long before motion is detected this camera shall be intensively recorded at Pre-record IPS. Press
+/-
buttons to adjust the value (0-10 seconds, discrete). Please note that the actual pre-record time may be shorter than the
value set if the total size of the pre-record pictures exceeds the pre-record buffer size of the system.
Post-record – to define how long after motion is detected this camera shall be intensively recorded at Event Record IPS. Press
+/-
buttons to adjust the value (0 second - 60 minutes, discrete).
Alarm Out – to define which Alarm Output will be triggered when motion of this camera is detected. Press
+/-
buttons to
select none (N/A) or one of the Alarm Outputs (1-2).
Buzzer – to activate the internal Buzzer or not when motion of this camera is detected. Press
ENTER
or
+/-
to check/uncheck
this item. The default setting is “
ˇˇˇˇ
” - checked.
Log – to log to event logs or not. Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
ˇˇˇˇ
” - checked.
Screen Message – to display the event message on the screen or not. Press
ENTER
or
+/-
to check/uncheck this item. The
default setting is “
ˇˇˇˇ
” - checked.
E-mail – to send the event e-mail to remote station or not. The e-mail will be sent to the predefined receivers when the event
is triggered. Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
––––
” - unchecked.
Detection Settings.. – used to setup the motion detection settings, including detection area and sensitivity, when motion is
detected for this camera. Press
ENTER
in Settings.. to call up Motion Detection Setup (as shown) for this camera. In Motion
Detection Setup, the video area is divided into many small grids, and the area with transparent grids is the area which will be
detected for motion, while gray grids not detected for motion. Besides, there is a (green) Mask window.
The following
is a brief description for the operations:
Numeric
Press these buttons to select the camera.
▲▼
◄►
Press these buttons to move the Mask window.
+/-
Press these buttons to resize the Mask window.
ENTER
Press this button to set/reset the area under the Mask window.
MODE
Press this button to set/reset the whole video area.
SEQ
- 20 -
Press this button to decrease the sensitivity, from 10 – 1, for the motion detection of this camera.
CALL
Press this button to increase the sensitivity, from 1 – 10, for the motion detection of this camera.
SEARCH
Press this button to test the motion detection of this camera. The detected motion will be shown on the screen. Press this
button again to stop testing.
ESC
Press this button to escape from Motion Detection Setup, and return to Motion Setup.
6.3 Alarm Setup
In Setup Menu display, press
▲▼
to change the highlighted option to Alarm, and then press
ENTER
to call up Alarm Setup
display as shown. The Alarm Setup allows the administrator to define the attributes for each alarm input, and the actions if it’s
triggered. There are up to 4 alarm inputs which can be connected to the system.
The general operations are
as follows
:
▲▼
◄►
Press these buttons to select the items.
Numeric
Press these buttons to select the alarm input.
COPY
(
)
Press this button to copy the settings of the focus alarm input to all the following alarm inputs. (eg. focus alarm input is 1, its
settings will be copied to those of alarm inputs 2-4.)
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press
ENTER
to
exit and save,
ESC
to exit without saving.
The following
is a brief description for each item and its specific operations:
Normal State – press
+/-
buttons to select N/A, Close or Open. Please check the signal type, normally close or normally open,
connected to the alarm input terminal on the rear panel of the system. If there’s no signal connected, please select N/A – Not
Available, and the following items will not be settable. The default setting is Open.
Focus Camera – the camera corresponding to this alarm input.
Duration – response duration to define at most how long (in seconds) the Alarm Out relay and the Buzzer will keep being
triggered after this alarm input is triggered. However, the Alarm Out relay and the Buzzer will be reset immediately once this
alarm input returns to normal. Press
+/-
buttons to adjust the value (3-60 seconds, discrete).
Goto Preset – to define the preset position to go to for the Focus Camera if this alarm input is triggered and the Focus Camera
is a PTZ camera. For more details about preset locations, please refer to
Chapter 7 PTZ Control
.
Pre-record – to define how long before this alarm input is triggered the Focus Camera shall be intensively recorded at
Pre-record IPS. Press
+/-
buttons to adjust the value (0-10 seconds, discrete). Please note that the actual pre-record time may
be shorter than the value set if the total size of the pre-record pictures exceeds the pre-record buffer size of the system.
Post-record – to define how long after this alarm input is triggered the Focus Camera shall be intensively recorded at Event
Record IPS. Press
+/-
buttons to adjust the value (0 second - 60 minutes, discrete).
Alarm Out – to define which Alarm Output will be triggered when this alarm input is triggered. Press
+/-
buttons to select
none (N/A) or one of the Alarm Outputs (1-2).
Buzzer – to activate the internal Buzzer or not when this alarm input is triggered. Press
ENTER
or
+/-
to check/uncheck this