5
4.3 LOCATION
WARNING
INSTALL UPRIGHT ON A WALL SUITABLE TO SUPPORT THE TOTAL WEIGHT OF THE
BOILER WHEN FULL OF WATER – 120 kg.
The location should be clean and dry with no presence of gases, explosives or flammable objects.
It is not suitable for installation outside and should be protected from moisture and frost.
The boiler must be sited so that the boiler and controls are not accessible to any persons whilst using a bath or
shower and there should be no possibility of water dripping or splashing onto the boiler or controls.
Electrical safety regulations for clearances must be followed if installed in a bathroom or shower area.
The boiler has an electric protection rating of IP20/IP2X.
Where possible the boiler should be sited to minimize the pipe distance to hot water outlets.
The power supply cable should be carefully routed and secured and provision made for a suitable isolation switch
and MCB/RCD.
4.4 DIMENSIONS & CONNECTIONS
200
80
245
285
355
435
535
8
3
450
3
160
200
30
80
350
300
760
265
DIMENSIONS & CONNECTION
A B
B
C
F
F
D
D
E
E
A cold water input 1/2"
B safety valve drain
C DHW.outlet 1/2"
D heating return 3/4"
E heating flow 3/4"
F electrical connection