11 TECHNICAL DATA  

 

 

CMX15BG CM15BG 

Frequency Hz

50

50 

Connection N~

 

    Output limited to 

15kW

;  Maximum intensity

A

21.7

21.7 

    Output limited to 

13kW

; Maximum intensity

A

21.7

21.7 

    Output limited to 

12kW

; Maximum intensity

A

21.7

21.7 

    Output limited to 

11kW

; Maximum intensity

A

21.7

21.7 

    Output limited to 

10kW

; Maximum intensity

A

21.7

21.7 

    Output limited to 

9kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

8kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

7kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

6kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

5kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

4kW

; Maximum intensity

A

13.0

13.0 

    Output limited to 

3kW

; Maximum intensity

A

13.0

13.0 

Connection 230V~ single phase 

1

1

 

    Nominal maximumintensity

15kW

 

A

65.2

65.2 

    Maximum converted intensity at 

13kW

 

A

56.5

56.5 

    Maximum converted intensity at 

12kW

 

A

52.2

52.2 

    Maximum converted intensity at 

11kW

 

A

47.8

47.8 

    Maximum converted intensity at 

10kW

 

A

43.5

43.5 

    Maximum converted intensity at 

9kW

 

A

39.1

39.1 

    Maximum converted intensity at 

8kW

 

A

34.8

34.8 

Maximum converted intensity at 

7kW

 

A

30.4

30.4 

Maximum converted intensity at 

6kW

 

A

26.1

26.1 

    Maximum converted intensity at 

5kW

 

A

21.7

21.7 

    Maximum converted intensity at 

4kW

 

A

17.4

17.4 

    Maximum converted intensity at 

3kW

 

A

13.0

13.0 

DHW available time with 

15kW 

min

5’49”

DHW available time with 

13kW

 min

6’42”

DHW available time with 

12kW

 min

7’16”

DHW available time with 

11kW

 min

7’56”

DHW available time with 

10kW

 min

8’43”

DHW available time with 

9kW

 min

9’41”

DHW available time with 

8kW

 min

10’54”

DHW available time with 

7kW

 min

12’27”

DHW available time with 

6kW

 min

14’32”

DHW available time with 

5kW

 min

17’26”

DHW available time with 

4kW

 min

21’48”

DHW available time with 

3kW

 min

29’04”

DHW available time with 

2kW

 min

43’36”

Weight

 

kg

70

32 

Insulatedsteelheaterheader

 

50 L stainless steel insulated DHWstore 

No CFC

Stainless steel plated resistance elements INCOLOY800

DHW

Stainless steel plated resistance elements INCOLOY800

Heating

 

6 litreexpansionvessel 

 

DHW2 litre expansion vessel 

Electronic regulation of heater modulation 

 

Electronic regulation DHW

Digital display 

 

0-4 barpressure gauge 

 

Acceleratorpump 

 

Automaticpurge 

 

 TRIACS silentpowerswitches 

 

Heatingflow detector 

 

100°Cheatingtemperaturelimiter 

 

80°CDHW temperature limiter 

3 barcentral heating relief valve 

 

7 barDHW relief valve 

DHWretentionvalve 

Ambientthermostatintake 

 

Anti-electrolysis DHW hoses. 

Water heating declared load profile 

L

Space heating energy efficiency class 

D

Water heating energy efficiency class 

D

Rated heat output 

kW

15

15 

Annual electricity consumption (AEC)

 

kWh

2806

Space heating energy efficiency (

η

s

%

37

37 

Water heating energy efficiency (

η

wh

%

37

Sound power level (L

WA

) dB

36

36 

included

1

 using connecting bridge included 

 

 

Содержание CM15BG

Страница 1: ...must be followed for the safe installation of the boiler Any problem fault or damage caused by the non observance ofthese instructions will not be covered under the manufacturer s warranty This manual...

Страница 2: ...rved and given to any new user The symbols used in the text are explained below WARNING This indication shows the possibility of causing death from electric shock WARNING This indication shows the pos...

Страница 3: ...he hot water supply to ensure a safe and economic supply of hot water All components for sealed system central heating are built in A suitable filling loop should be fitted externally to comply with w...

Страница 4: ...nts before commencing SITING THE BOILER WARNINGWall and fixings must be suitable to support the total weight CMX boiler when full is 120 kg CM boiler when full is 50 kg Allow sufficient clearance and...

Страница 5: ...current building regulations Installation should also be in accordance with the relevant British Standards and Codes of Practice including the following BS 5449 Forced circulation hot water systems BS...

Страница 6: ...r splashing onto the boiler or controls Electrical safety regulations for clearances must be followed if installed in a bathroom or shower area The boiler has an electric protection rating of IP20 IP2...

Страница 7: ...to enable easy access for servicing Ensure sufficient space to make all water connections including the outlet pipes for the heating and hot water safety valves which should be routed to a suitable d...

Страница 8: ...able caps Heating Flow Return These connections are for connection to 22mm pipe using the tails provided Service valves should be installed at this position to allow the boiler to be isolated for main...

Страница 9: ...d with a continuous fall to a safe yet visible point where any discharge cannot cause damage or injury 4 8 DHW DISCHARGE PIPE WORK The CMX electric combi boiler range incorporates a 50 L unvented hot...

Страница 10: ...ection to Mains Supply The CM15BG and CMX15BG boilers must be installed in premises having a system impedance of not more than 0 25 j0 25 The CM15BG and CMX15BG boilers comply with the technical requi...

Страница 11: ...the connection block as shown The terminal connection block is at the rear right hand side of the boiler and is accessed after removing the boiler front panel The supply cable should be safely routed...

Страница 12: ...ing from t oned upside d the switches t hree phase su elected output ED HEAT OU ial to confirm f electronic card 1 mum heat outp NS WHERE TH L MUST BE RE also be limited best hot wate mum but will s p...

Страница 13: ...remains in the system or there is insufficient pressure or flow rate the boiler will fail to operate and display fault E3 A LED indicator informs about the operating status of the pump Green correct...

Страница 14: ...SWITC GE COULD O gene on th Turn of th Main switc i temperatu nd other essages Red dot shows heating heating lements on duty 3 ghly prior to BS7593 BS54 boiler Any cle efully followed RESSURE REL T O...

Страница 15: ...ay o DHW produ W and the elem desired tempe rature can be t the setting t s or instantly between 20 a ver the centra m temperatur D n 1 The same but he butto y will show th uction over ce ments are en...

Страница 16: ...n fo er will be lock will function n e same button there is a fail ON l automatically activity The p 1 as room therm button Pushin ay will show th e of the water o adjust the v w seconds or C and 85 C...

Страница 17: ...3 Fault E3 continued System resistance too high or blockage Check pump speed 3 Check pump duty sect 4 9 Open all radiator valves Install system by pass Fault E5 displayed Error in configuration for ma...

Страница 18: ...ect the bo dition are he heating sys Check as sho m debris or a y restrictions s ostatic In th the boiler dur ever the guida g of an automa inimum flow r asteful circula OUTPUT actual heat po that mom...

Страница 19: ...most rigorous environmental requirements For example the selection of materials involves guaranteeing their biodegradability re use and recycling When this boiler s long useful life is over it must b...

Страница 20: ...3kW A 13 0 13 0 DHW available time with 15kW min 5 49 DHW available time with 13kW min 6 42 DHW available time with 12kW min 7 16 DHW available time with 11kW min 7 56 DHW available time with 10kW min...

Страница 21: ...arries the structions and 5 2 CLARACI De acuerdo DECLARAT According to LNUR S A LNUR S A I El Nogal V 8110 Algete Caldera modu Caldera modu CMBG Heat CMXBG Hea GABARR N CM15BG CM pecificacion ular al...

Страница 22: ...21 NOTES...

Страница 23: ...22 13 WIRING DIAGRAMS...

Страница 24: ...ufact ELNU Traves a de V 28110 Alge Telephone 3 ement the man dicates that this e collection po osed of corre ealth which co cycling of this p hased the prod plier UK Ltd 0 1942 67011 nur co uk nur co...

Отзывы: