background image

PDFMAILER.DE

31

BUTTONHOLE SENSOR

To remove:

1.

Remove the front cover (see page 

11

).

Move it so that the connectors can be pulled out.

2.

Remove the screw 

A

, then remove the buttonhole sensor 

B

 from the sensor plate 

C

.

3.

Pull out the connector of buttonhole sensor 

D

 from the k-board.

4.

Pull out the cord of buttonhole sensor from the cord guide 

E

 and then remove the

buttonhole sensor 

B

.

To attach:

1.

Attach the buttonhole sensor 

B

 with screw 

A

. Pull the sensor forward so that it touches the

setting plate. Make sure it doesn’t touch the buttonhole shield plate 

F

, see illustration.

2.

Pass the cord as illustrated and attach the front cover.

After replacing the buttonhole sensor, sew a few buttonholes. If something is abnormal, 

adjust the “Buttonhole lever” (see page 

22

).

Содержание 6005 heirloom edition

Страница 1: ...PDFMAILER DE 11 99 Printed in Switzerland 395902 42 Elna 6005 Heirloom Edition SERVICE MANUAL...

Страница 2: ...edle centring 13 Needle bar height 14 Hook and feed timing 15 Clearance 16 Backlash of hook drive gear and lower shaft gear 17 Feed dog height 18 Needle bar swing sensor 19 Upper and lower tension 20...

Страница 3: ...ND WIRING Each connector should be connected as follows A THREAD TENSION SWITCH G ZIGZAG STEPPING MOTOR B BUTTONHOLE SENSOR H DC MOTOR C UPPER SHAFT SENSOR I F BOARD D SEWING LIGHT J K BOARD E C BOARD...

Страница 4: ...PDFMAILER DE GENERAL TROUBLE SHOOTING PROCEDURE 2 MACHINE DOESN T WORK WELL...

Страница 5: ...is jammed up 5 Feed dog teeth are worn 1 Adjust the presser bar level to make the pressure stronger 2 See mechanical adjustment Feed dog height 3 Raise the feed dog level 4 Make sure to bring both ne...

Страница 6: ...n Guide the fabric gently while sewing Page 19 6 Noisy operation 1 Backlash between shuttle hook gear and lower shaft gear is too great 2 Lower shaft gear is loose 3 Inappropriate belt tension 4 Not e...

Страница 7: ...Replace the printed circuit board K Then turn on the power switch If nothing is happened turn off the power Switch and go to the Step 2 Step 2 Replace the printed circuit board A Then turn on the powe...

Страница 8: ...and LCD shows Spool If not working replace the following parts in order and recheck 1 Printed circuit board K 2 Printed circuit board A 5 Step Tension switch 1 Turn the thread tension dial 1 Buzzer so...

Страница 9: ...roperly replace the following parts in order and recheck 1 Printed circuit board K 2 Printed circuit board A 11 Step Buttonhole 1 Press the Reverse button 1 Buzzer sounds and LCD shows DC Motor 2 The...

Страница 10: ...ook C is released To attach 1 Attach the face plate 2 Tighten the set screw B and attach the cap A TOP COVER To remove 1 Remove the set screw F 2 Lift up the handle H and remove the set screw E 3 Clos...

Страница 11: ...ILER DE 9 BELT COVER To remove 1 Remove the cap A 2 Remove the screws B and D 3 Lift up the handle F and loosen the screws E To attach 1 Attach the belt cover C with the screws B D and E 2 Attach the...

Страница 12: ...move 1 Remove the screw A and 4 screws B 2 Remove the base plate C To attach 1 Reverse this procedure Bed cover To remove 1 Remove the 2 screws D 2 Remove the bed cover E To attach Move the drop lever...

Страница 13: ...move 1 Remove the face cover top cover belt cover and bed cover see pages 8 9 and 10 2 Remover the screw A and loosen the screws B C D E F and G 3 Pull out the connector H and remove the front cover K...

Страница 14: ...r see pages 8 9 and 10 2 Loosen the screws A B C and D 3 Remove the cap E and remove the screw F 4 Remove the rear cover while pulling it toward you and pushing it to the left Unhook the projection G...

Страница 15: ...gzag width the distance between both sides of needle slot in the needle plate and the needle positions should be equal If not adjust as follows 1 Turn on the power switch 2 Select pattern 1 or pattern...

Страница 16: ...by turning the handwheel toward you 1 Remove the needle plate and bobbin holder 2 Turn on the power switch and select pattern no 2 3 Turn the handwheel toward you until tip of shuttle hook meets the r...

Страница 17: ...cam should be in its lowest position If not loosen the set screws A of upper shaft belt wheel With the needle bar in its lowest position hold the handwheel in place while turning the upper shaft belt...

Страница 18: ...itch and select pattern 2 4 Loosen the set screws A B C and slightly loosen the hinge screw C 5 Turn the handwheel and adjust the clearance between the master needle and the point of shuttle hook in t...

Страница 19: ...of the shuttle hook A is between both ends B of feed dog 4 Rotate the hook race clockwise and counter clockwise by finger Check the play It should be within 0 8 mm If there is more than 0 8 mm adjust...

Страница 20: ...t at 3 and the presser foot is lowered 1 Set the pressure dial at 3 and lower the presser foot 2 Turn on the power switch 3 Remove the bed cover see page 10 4 Turn the balance wheel toward you to set...

Страница 21: ...h to maximum 3 Slowly turn the handwheel toward you until the needle starts to swing If higher than 7 5 mm loosen the screw C and turn the sensor disk F in direction A If lower than 6 3 mm loosen the...

Страница 22: ...F to 3 2 Open the face plate and adjust the thread tension by turning the thread tension screw D in the direction of A for loosen the tension B for tighten the tension 3 Close the face plate Check Th...

Страница 23: ...pushing the reverse button and then select the pattern No 8 within 2 5 seconds CHECK PATTERN 8 will appear in the screen 2 Set the feed balancing dial D at the standard setting mark 3 Sew the pattern...

Страница 24: ...e power switch on while pressing the reverse button and then press BH1 at once BH SENSOR H or L will appear in the screen 2 Lower the buttonhole lever E Then leaves the clearance of 1 6mm between the...

Страница 25: ...6 mm adjust as follows To adjust 1 Remove the face cover see page 8 2 Raise the presser foot lever B and loosen the screw D on the presser bar holder E 3 Adjust the distance between the zigzag foot A...

Страница 26: ...wer the threader knob A to its lowest position 2 Loosen the screw B and remove the threader plate Fig A To change the needle threader 1 If the hook of the threader plate F touches left or right side l...

Страница 27: ...unit B To attach 6 Reverse this procedure To change the fuse 1 After removing the c board case unit B remove the 5 screws H I J K and L to pull out the c board C 2 Replace the fuse M in the fuse holde...

Страница 28: ...Remove the C board case see page 25 4 Detach the connectors A and B 5 Remove the screws C and D 6 Take out the transformer F To attach 1 Set the rear side of the transformer F on the supporter E 2 Tig...

Страница 29: ...move the front cover and the rear cover see page 11 and 12 2 Remove the C Board case unit C see page 25 Move it so that the connectors can be pulled out 3 Pull out connectors A and B 4 Remove the 2 sc...

Страница 30: ...R DE A BOARD 28 To remove 1 Remove the front cover see page 11 2 Pull out the 8 connectors A B C D E F G and H 3 Remove the 3 screws J 4 Take off the A Board 5 Install a new A Board and reverse this p...

Страница 31: ...e connectors of the printed circuit boards F or K and then remove the printed circuit boards F or K To attach 1 Insert the connectors of the printed circuit boards F or K 2 Insert the lever into the g...

Страница 32: ...t the motor connector from the A board 6 Remove screws C and D 7 Take out the motor To attach 1 Set the motor in machine and replace screws C and D 2 Snap the motor connector into the a board 3 Attach...

Страница 33: ...4 Pull out the cord of buttonhole sensor from the cord guide E and then remove the buttonhole sensor B To attach 1 Attach the buttonhole sensor B with screw A Pull the sensor forward so that it touche...

Страница 34: ...oard 3 Remove the 3 screws A and remove the A circuit board E 4 Push the holders B and remove the upper shaft sensor C To attach 1 Attach the new upper shaft sensor C unit into the setting plate After...

Страница 35: ...MOTOR To remove 1 Remove the C board case unit and receptacle unit see page 25 and 27 2 Remove the 3 screws A and the A board setting plate 3 Remove the 2 screws B 2 screws C and remove the motor D To...

Страница 36: ...nap ring B and the 2 screws A 5 Remove the feed stepping motor C together with feed rod D To attach 1 Slide the feed rod D onto the feed arm pin F 2 Then attach the feed stepping motor by tightening t...