PRESSER BAR HEIGHT AND ALIGNMENT
To check:
1.
Raise the presser foot lever
B
.
2.
The distance between the zigzag foot
A
and the needle plate
C
should be 6.0 mm.
If the height is greater or less than 6 mm, adjust as follows.
To adjust:
1.
Remove the face cover (see page
8
).
2.
Raise the presser foot lever
B
and loosen the screw
D
on the presser bar holder
E
.
3.
Adjust the distance between the zigzag foot
A
and the needle plate
C
to 6.0 mm.
4.
Tighten the screw
D
securely.
Note:
When you tighten the screw
D
, make sure that both sides of the zigzag foot
A
are paralleled
with the feed dog slits
G
.
5.
Attach the face cover.