Gold Solo Double Twitter Installation Guide
MAN-G-SOLTWIB_160 (Ver. 1.005)
|
Main, Control, and Motor Power|
www.elmomc.com
34
Table of Contents
8.1.4.4.
Single Power Supply (PN
G-SOLTWIDXXX/YYYEES
V
)
The Gold Solo Double Twitter 80V and 100V can be ordered (with V suffix) with VL+ already
internally connected to the VP+.
The single power supply is selected by its part number (VL+ connected to VP+) which describes the
absolute maximum VP+ and VL+ voltage which must be < 95VDC, under all conditions, to prevent
VL+ supply failure.
A single power supply can be used for the main and control power in the range of 11VDC to 95VDC.
The following figure describes a single connection of main power and control:
Figure 14: Single Power Supply (VP+ <95V) Connection Diagram
Note: