![Elmo Gold Solo Double Twitter Series Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/elmo/gold-solo-double-twitter-series/gold-solo-double-twitter-series_installation-manual_2394495030.webp)
Gold Solo Double Twitter Installation Guide
MAN-G-SOLTWIB_160 (Ver. 1.005)
|
Main, Control, and Motor Power|
www.elmomc.com
30
Table of Contents
8.1.4.
Main Power and Control Supply
This section describes the Main Power and the Control supply connector.
8.1.4.1.
Main Power
The isolated DC power source is not included with the Gold Solo Double Twitter.
Pin
Function
Cable
Pin Positions
VP+ DC Pos. Power input
Power
PR
Power return
Power
PE
Connection earth
Power
Table 3: Main Power Terminals
Connect the DC power cable to the VP+ and PR terminals on the main power connector.
To connect the Gold Solo Double Twitter to the DC power source:
1.
The source of the VDC power supply must be isolated from the Mains.
2.
Verify that the rectified VDC is indeed within the range of the drive.
3.
Connect the VP+ and PR wires to the terminals on the servo-drive as shown in Figure 10.
It is highly recommended to twist the two DC main power cables at intervals of 10 cm.
Figure 10: Connecting the Main Power Wires
4.
Connect the PE to the closest earth connection near the power supply.
5.
Connect the PR to the closest earth connection near the power supply.
6.
Before applying power, first verify the polarity of the connection.