Previously stored tables can be opened again using the “load table” button. With this
process, the values in the current table will be overwritten! In this way it is possible, for
example, to edit existing tables or to continue dosing with an as yet incomplete table.
10
Exchanging data with a PC
To exchange data, the (optional) supplied programme should be installed and started on the
PC.
Using the cable provided, the SPG10 display device should be connected into a free USB port
on the PC. As the power is also supplied via the USB cable, the display device can be
disconnected from the SPG20 control module.
Now, all of the data recorded on the SPG10 can be transmitted and analysed. Further
information can be found in the manual for the SPG10 PC programme.
11
IDS03 Volume Sensor
When dealing with the volume sensor some points must be
considered: the differential pressure sensor of the volume sensor
has no contact with the medium to be measured, this allows a
measurement of various problematic or even aggressive liquids. In
addition, air is pumped through the measuring tube by means of a
diaphragm pump. This ensures constant conditions, thus making the
measurement insensitive to temperature changes. So that this
process can work properly the end of the tube must remain open for
the egress of air. Otherwise, the device switches off and will indicate
excess pressure. Do not use a high pressure cleaner for
cleaning!
Standby-mode:
If the SPG10 sprayer computer switches to standby (after about 5
min. of inactivity) the diaphragm pump is also switched off and the
content measurement ceases (indicator falls to zero).
11.1 Instructions on installing the volume sensor
•
The measuring tube must reach almost to the ground; only a small gap must remain to
allow the egress of air.
•
The stainless steel tube must be cut off cleanly and deburred inside and outside.
Fig. 43: IDS03 volume sensor
The stainless steel
measureing tube
can be removed
from the device
with a screw.