Set the initial value of frequency P0.10 (frequency preset) values. Can bring through a keyboard
▲
keys and
▼
keys (or multi-
function input terminal of the UP and DOWN) to change the set frequency value of the inverter. Inverter after the power is off
and the power is on again, set frequency values revert to P0.10 (digital frequency setting preset ) values.
1: digital setting (power lost memory)
Set the initial value of frequency P010( frequency preset )values. Can be brought by a keyboard
▲
,
▼
keys (or multi-function
input terminal of the UP and DOWN) to change the set frequency value of the inverter.
Inverter after the power is off and the power is on again, set frequency electric moment for the last set, through the keyboard
bring
▲
,
▼
keys or terminal correction by the memory of UP and DOWN.
What need to remind is, P0.23 set for "digital frequency setting down memory selection", P0.23 is used to select the inverter when
the inverter stops, P0.23 is used to select whether inverter memorizes the freq or is reset during stopping time,P0.23 is related to
the stop, isn’t related to the drop memory, pay attention in the application.
2: FIV
3: FIC
4: Reserved
ED2000 panel provides two analog input terminal (FIV, FIC).Among them, the FIV is from 0Vto 10V voltage input, FIC is from 0V to
10V voltage input, can also be used for 4 - 20 mA current input, FIV, FIC of the input voltage value, the corresponding relationship
with the target frequency, users are free to choose. ED2000 provide 5 set of corresponding relation curve, three groups of curve
for linear relationship (2 point correspondence), three groups of curve for linear relationship (4 point correspondence), the user
can set through the P5 group and C6 group function code .
P5.33 function code is used to set the FIV ~ the FIC two-way
analog input, respectively select which of the five groups of curves, five specific corresponding relation curves, please refer to the
descriptions of P5, C6 group function code.
5: Pulse frequency (S3) given is given by terminal pulse. Pulse signal given specifications: voltage range of 9v~ 30v and frequency
range of from 0 kHZ to 100 kHZ. Input pulse can only be given from multifunctional input terminals S3.
S3 terminal input pulse frequency and the corresponding set of relations, through the P5.28 - P5.31 setting, the corresponding
relations between for 2 linear point correspondence .the linear relation between the corresponding set of input pulses 100.0%,
refer to the relative maximum frequency P0.12 percentage.
6: More instructions to choose and more instructions operation mode: select speed through the digital input S terminal state of
different combinations, ED2000 can set up 4 multispeed instruction terminals and select 16 state of those terminals. Through the
function of the PC group code corresponding to any 16 Multistage instruction .The Multistage instruction is referred to the
percentage of the maximum frequency P0.12
Digital input terminal function S terminal as multispeed selection terminal need to be done in group P5 corresponding settings,
please refer to the specific content P5 group of related function parameters.
7: Simple PLC
When frequency source is in simple PLC mode, frequency source of inverter can run between any frequency source from 1 to 16,
the hold time from 1 to16 frequency instruction and their respective acc /dee. time can also be set by the user. The specific content
can refer to PC group.
8: PID
Select the process of PID control output as the operating frequency. Commonly used in the scene of the closed loop control
technology, such as constant pressure closed loop control, constant tension closed-loop control, etc. Application of PID as
frequency source, you
need to set up "PID" PA group related parameters.
9: Communication given
the main frequency source is given by the upper machine through the way of communication. ED2000 support communication
methods: RS - 485.
P0.05
Auxiliary frequency
source Y selection
Default
Setting Range
0
digital setting(P0.10 preset frequency, can
modify the UP/DOWN, power lost don't memory)