4. Installation Preparation
CAUTION
Potable Water
Only
Do not connect this product to a water source that is
microbiologically unsafe or of unknown quality.
Always connect the unit to a water main that supplies
drinking water only.
Lifting Hazard
Use two people to move the unit. The Smartwell
unit weighs 200 lbs.
NOTICE
Do not allow the unit to freeze.
1. Elkay recommends a water pressure of 40 to 105
psi on our cooler products. A pressure regulator
integrated into the unit reduces the pressure to an
optimal 50 psi.
NOTICE
Water pressure that does not
meet the minimum pressure
requirement of 40 psi can cause damage to the
internal components. Low pressure may also
affect the performance of the unit and the taste of
the beverage.
2. A standard 3/8” diameter inlet water line is
recommended (copper or FDA-safe plastic).
3. Use care when opening and removing the packaging
to prevent damage to the product.
CAUTION
Wear protective
cut-resistant gloves to
protect against sharp edges from sheet metal
components.
a. Inspect the product for any shipping damage
and report it immediately to your dealer or lease
provider. Installation of a damaged product will void
the warranty.
b.
Confirm that all accessory parts have been
included for the proper installation of this product.
Contact your dealer or lease provider if damaged
parts are found.
491
Factory Supplied Parts
Description
Part Number
Qty.
Coil of 3/8” O.D. water tubing (blue)
1000002708
1
Coil of insulation for 3/8” water tubing (black) 1000002707
1
Coil of 1/4” O.D. CO
2
tubing (white)
1000002706
1
Quick connect CO
2
regulator
1000002468
1
Quarter-turn water supply shut-off valve
1000002470
1
Filter Element
51299C
1
Power Cord
1000004619
1
Ethernet Cable (15 feet)
1000005025
1
Wi-Fi Extender
1000005047
1
CO
2
Bottle Wall Mounting Bracket
1000005199
1
Keys for Upper and Lower Panel Locks
—
2
4.
Required floor space.
D = 32.3" (82 cm)
W = 33.5" (85.1 cm)
H = 92" (233.7 cm)
The unit requires 6” (15 cm) of space on left and right
side, and 12” (30.5 cm) of space between back of unit
and wall to accommodate 20 lb. CO
2
tank (installed
per local regulations by a certified agent).
If using a floor stand to hold CO
2
tank, then a minimum
of 18” of space is required between the back of the
unit and the wall to accommodate the CO
2
tank.
An open space of 36” (91.5 cm) from the top of the
unit to the ceiling is also required.
D
W
H
490