ID 983-985 LX (/C /CK) HACCP

7/12

PAR.

Fot

FAd 
Fdt 
dt
dFd

FCO

Fod

FdC

Fon

FoF

Att

AFd
HAL (5)

LAL (5)

PAO (!)

(8)

dAO

OAO

tdO

tAO (8)
dAt

EAL
AOP

PbA

SA3 
dA3

dSd

dLt

OFL

dOd

dAd

L00

L01

L02

L03

L04

L05

D

DE

ES

SC

CR

RIIP

PT

TIIO

ON

N

Fan on-start temperature. Fan start temperature; if the temperature read by the evapora-
tor is lower than the value set for this parameter, the fans remain deactivated. The value
is positive or negative and, depending on the FPt parameter, could represent the temper-
ature in absolute value or relative to Set point. 
FAn differential. Fan activation intervention differential (see par. “FSt” and “Fot”). 
Fan delay time. Delay time between start-up of fan after defrosting. 
drainage time. Dripping time. 
defrost Fan disable. Used to select exclusion of evaporator fans during defrosting. 
y = yes; n = no. 
Fan Compressor OFF. Used to select fan stop when compressor is switched OFF. 
y = fans active (with thermostat; in response to the value read by the defrost probe, see
“FSt” parameter); 
n = fans off; 
dc = duty cycle (using parameters “Fon” and “FoF”). 

Fan open door open. Used to select the fan stop when door is open and fan re-start
when door is closed (if they were active). n=fans stop; y=fans unchanged. 
Fan delay Compressor off. Fan switch off delay time after compressor stop. In minutes.
0= function excluded 
Fan on (in duty cycle).
Time fans are ON in duty cycle. Use of fans in duty cycle mode; valid for FCO = dc and
H42=1 (probe 2 present) (evaporator)) 
Fan OFF (in duty cycle).
Time fans are OFF in duty cycle. Use of fans in duty cycle mode; valid for FCO = dc and
H42=1 (probe 2 present) (evaporator))

ALARMS (folder with “AL” label)

Alarm type. Parameter “HAL” and “LAL” modes, as absolute temperature values or as dif-
ferential compared to the Set point. 
0 = absolute value; 1 = relative value. 
Alarm diFferential. Alarm differential. 
Higher ALarm. Maximum alarm. Temperature value (considered as distance from Set
point or as an absolute value based on Att) which if gone above triggers the alarm signal.

See Max/Min. Alarm Diagram;

Lower ALarm. Minimum alarm. Temperature value (considered as distance from Set point
or as an absolute value based on Att) which if gone below triggers the alarm signal. 

See Max/Min. Alarm Diagram;

Power-on Alarm Override. Alarm exclusion time after instrument start-up, after a power
failure. 
defrost Alarm Override. Alarm exclusion time after defrost.
(*)To prevent false HACCP alarms after a defrost cycle, signalling is inhibited for a period
of time set by this parameter 
Alarm signal delay after disabling digital input (door open). Alarm refers to a high and
low temperature alarm. 
time out door Open. Time out after alarm signal following digital input disabling (door
open). 
temperature Alarm Override. Temperature alarm signal delay time. 
defrost Alarm time. Alarm signal for defrost end due to time-out. 
n = does not activate alarm; y = activates alarm. 
External Alarm Lock. External alarm to lock controllers (n=does not lock, y=locks). 
Alarm Output Polarity. Polarity of alarm output. 
0 = alarm active and output disabled; 
1 = alarm active and output enabled. 
Configuration of temperature alarm on probe 1 and/or 3. 
0 = alarm on probe 1 (thermostat control); 
1 = alarm on probe 3 (display); 
2 = alarm on probe 1 and 3 (thermostat control and display). 
3 = alarm on probe 1and 3 (thermostat control and display) on external threshold 
Probe 3 alarm set point (display) 
Probe 3 alarm differential (display)

LIGHT AND DIGITAL INPUTS (folder with “Lit” label)

Light relay enable from door switch. 
n = door open, light does not turn on; 
y = door open, light turns on (if it was off). 
Light relay disabling (switch off) delay (cell light). The cell light will remain on for dLt
minutes after closing the door if the dSd parameter is set to do this. 
Light switch always disables light relay. Enables switching off with light button even if the
delay after closing the door set by dLt is active. 
Door switch switches off loads. When commanded by the digital input, programmed as
door-switch, it stops all the loads when the door is opened and re-starts them when the
door is closed (observing any timings in progress). 
Digital input activation delay

(FOR /CK MODELS ONLY) LINK CONTROLLER(folder with “Lin” label)

Selects the instrument as Master (0), Slave (from 1 to 7), Echo (0, in this case the Echo
serves as a repeater for the Master even if connected to a Slave). 
Refers to Master only. Number of Slaves in network (from 0 to 7). Per Slaves/Echoes leave
value =0 
Presence of local Echoes referring to single Slave. 0 = Local echo not present; 1 = Echo
present and shares the Slave display at a set rate; if Master or Slave, it determines if the
device is active and shares its local display at a set rate. 2 = the Echo shows the display
of the associated Slave (Slave and associated Echo must have the same address L00). If it
is directly connected to the Master, it displays the Master display. 

Refers to Master and Slave. Simultaneous/sequential defrosting. Master: n = simultaneous;
y = sequential. Slave: n = ignore; y = accept. 
Refers to Slave only. Distributed display. n = the Slave displays local values; y = the Slave
displays Master display 
Refers to Master and Slave. Master: n = does not ask Slaves to activate remote functions;
y = asks Slaves to activate remote functions. Slave: n = ignores activation of remote func-
tions from Master; y = accepts activation of remote functions from Master.

DEFAULT

-18.0

2.0 



y

y

n

0

0

0

0

2.0 

50.0

-50.0

0

120min

0

0


n


1

0

2.0

y

0

n

n

0

0

0

0

n

y

n

RANGE

-50.0..150.0

1.0…50.0

0...250
0...250 

n/y

n/y/dc

n/y

0..99

0..99

0..99

0/1

1.0...50.0

LAL...150.0

-50.0...HAL

0...10

0..999

0…10

0...250

0...250 

n/y

n/y 
0/1

0…3

-50.0…150.0

-30.0…30.0

n/y

0…31

n/y

n/y

0…255

0...7

0...7

0/1/2

n/y

n/y

n/y

VALUE*

LEVEL**

2




1

1

2

2

2

2

2


1

1

1

1

2

2

1

2


2

2


2

2

2

2

2

2

2

2

2

2

2

2

U.M.

°C/°F

°C/°F 

min 
min 
flag

num

flag

min

min

min

flag

°C/°F
°C/°F

°C/°F

hours

min

hours

min

min 
flag

flag 
flag

min

°C/°F
°C/°F

flag

min

flag

flag

min

num

num

num

flag

flag

flag

Содержание 983LX/CK HACCP

Страница 1: ...t be changed Real Time Clock C CK models By pressing the set button when the rtc label appears the label d00 days is displayed Use the UP and DOWN buttons to set days If you do not use the buttons for...

Страница 2: ...operation is confirmed by pressing the set button If the operation is successful a y is displayed whereas if it is unsuc cessful an n will be displayed Download from reset Connect the copy card with...

Страница 3: ...slave and echo devices The distance between one device and another must be 7 metres maximum whereas the maximum distance between the first and last instrument in the network must be approximately 50m...

Страница 4: ...ther mostat control probe probe1 and or dis play probe probe 3 The temperature limits are defined by the HAL maximum alarm LAL minimum alarm and PbA alarm configuration on probe 1 3 or both parameters...

Страница 5: ...gital outputs MODEL ID 985LX 4 outputs on relays first output A SPDT 8 3 A 250Va second and third output B C SPST 8 3 A 250Va fourth output D SPST 5 2 A 250Va MODEL ID 983LX 2 outputs on relays A SPDT...

Страница 6: ...RTC is enabled 1 equipment operating hours defrost counting is always active when the machine is on and starts at each power on 2 compressor stop Every time the compressor stops a defrost cycle is per...

Страница 7: ...tes alarm External Alarm Lock External alarm to lock controllers n does not lock y locks Alarm Output Polarity Polarity of alarm output 0 alarm active and output disabled 1 alarm active and output ena...

Страница 8: ...ature used by controllers not the temperature displayed that remains unchanged 2 adds to temperature displayed that is also used by controllers Low display Label Minimum value the instrument is able t...

Страница 9: ...output configurability 1 A Same as H21 2 defrost default ID 985LX C CK MODEL ONLY Digital output 3 configurability C Same as H21 3 fans default ID 985LX C CK MODEL ONLY Digital output 4 configurabili...

Страница 10: ...or safety reasons the instrument must be installed and used in accordance with the instructions supplied Users must not be able to access parts with dangerous volt age levels under normal operating co...

Страница 11: ...S CnF Fpr set level 1 par level 1 par level 1 par level 1 par set set set PA2 level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par CP dEF FAn AL set set set...

Страница 12: ...output 1st evaporator A 15 16 N O compressor relay output B 15 17 N O fan relay output C 18 19 N O defrost relay output 2nd evaporator D ID 983LX C CK 1 4 Probe input 3 2nd evaporator 12 13 N O defros...