ID 983-985 LX (/C /CK) HACCP
8/12
PAR.
L06
E00
E01
E02
E03
dEA (!)
FAA (!)
LOC
PA1
PA2***
ndt
CA1
CA2
CA3
CA
LdL
HdL
ddL
Ldd
dro
ddd
H00 (!)
H02
H06
H08
H11 (7)
H12 (7)
DESCRIPTION
Locks resources (compressors, fans, etc) at the end of defrosting. n=no; y=yes NOTE:
related to Ldd parameter which has priority over L06 (see)
(FOR /C /CK MODELS ONLY ) DAY/NIGHT CONTROLLER (night and day)
(folder with “nad” label)
Functions enabled during events: 0 = control disabled. 1 = reduced set point; 2 =
reduced set+light; 3 = reduced set+light+aux. 4= instrument off
Hours/minutes of start of event. Sets start time of event. Starting from this time, the
“NIGHT” mode will be enabled. The duration is determined by EO2.
Duration of event. Sets duration of event (for type of event, see E00)
Blocking/unblocking daily or holidays defrosting. 0= “work days” defrost sequence
defined by par. dE1…dE8; 1= “festive/holidays” defrost sequence defined by par. F0…F8;
N.B.: does not affect timed defrosting like Every Day (same defrost sequence for
working days/holidays). COMMUNICATION (folder with “Add” label)
dEvice Address. Indirizzo dispositivo: indicates the device address to the management
protocol.
FAmily Address. Indirizzo famiglia: indicates the device family to the management proto-
col.
DISPLAY (folder with “diS” label)
(keyboard) LOCK. Keyboard locked. However, you can still access the parameter pro-
gramming menu and modify parameters including the status of this parameter to allow
keyboard unlocking. y = yes (keyboard locked); n = no.
PAssword 1. When enabled (value is not 0) it represents the access key to level 1 para-
meters.
PAssword 2. When enabled (value is not 0) it represents the access key to level 2 para-
meters. number display type.
Display with decimal point. y = yes (display with decimal point); n = no (only whole num-
bers).
CAlibration 1. Calibration 1. Positive or negative temperature value added to the value
read by probe 1, based on “CA” parameter settings.
CAlibration 2. Calibration 2. Positive or negative temperature value added to the value
read by probe 2, based on “CA” parameter settings.
CAlibration 3. Calibration 2. Positive or negative temperature value added to the value
read by probe 3, based on “CA” parameter settings.
CAlibration Intervention. Offset intervenes on display, thermostat control or both.
0 = only modifies the temperature displayed;
1 = adds to the temperature used by controllers, not the temperature displayed that
remains unchanged;
2 = adds to temperature displayed that is also used by controllers.
Low display Label. Minimum value the instrument is able to display.
High display Label. Maximum value the instrument is able to display.
defrost display Lock. Display mode during defrosting.
0 = displays the temperature read by the thermostat control probe;
1 = locks the reading on the temperature value read by thermostat control probe when
defrosting starts until the next time the Set point value is reached;
2 = displays the label “deF” during defrosting until the next time the Set point value is
reached (or until Ldd expires).
Lock defrost disable. Time-out value for unlocking display (dEF label) if reaching the set
point takes too long during defrosting or if the Link (Master-Slave) communication fails
(E7 error)
display read-out. Select °C or °F to display temperature read by probe. 0 = °C, 1 = °F.
N.
B: switching from °C to °F DOES NOT modify set points, differentials, etc. (for
example set point=10°C becomes 10°F).
Selection of the value type to be displayed.
0 = Set point;
1 = probe 1 (thermostat control);
2 = probe 2 (evaporator);
3 = probe 3 (display).
CONFIGURATION (folder with “CnF” label)
(!) Selection of probe type, PTC or NTC. 0 = PTC; 1 = NTC. Button activation time if but-
tons are configured for a second function. For the ESC, Up and DOWN buttons config-
ured for a second function (defrost, aux, etc) the time for quick enabling is set.
Aux is an exception and has a set time of 1 second button/aux input/door switch light
active when instrument is off (but powered) Stand-by operating mode. 0= only display
switched off; 1= display on and controllers locked; 2= display off and controllers locked;
Configuration of digital inputs/polarity.
0 = disabled;
1 = defrost;
2 = reduced set point;
3 = auxiliary;
4 = door switch
5 = external alarm
*6 = disables storage of HACCP alarms (*only in HACCP models)
7 = stand-by (ON-OFF)
8 = maintenance request
Configuration of digital inputs/polarity.
Same as H11
DEFAULT
y
0
0
0
0
0
0
n
0
0
n
0
0
0
2
-50.0
140.0
1
0
0
1
1
5
y
2
0
0
RANGE
n/y
0...4
0...23/0...59
0…99
0/1
0...14
0...14
n/y
0...250
0...255
n/y
-12.0...12.0
-12.0...12.0
-12.0...12.0
0/1/2
-55.0...302
-55.0..302
0/1/2
0…255
0/1
0/1/2/3
0/1
0...15
n/y
0/1/2
-8…8
-8…8
VALUE*
LEVEL**
2
2
2
2
2
1
1
1
1
2
1
1
1
1
2
2
2
1
1
1
2
1
2
2
2
2
2
U.M.
flag
num
hours/min
hours
flag
num
num
flag
num
num
flag
°C/°F
°C/°F
°C/°F
num
°C/°F
°C/°F
num
min
flag
num
flag
sec
flag
num
num
num
HACCP PARAMETERS (folder with “HCP” label) SEE relevant paragraph and table 2