ID 983-985 LX (/C /CK) HACCP

6/12

PAR.

diF

HSE 
LSE
OSP

Cit

CAt

Ont (1)

OFt (1)

dOn
dOF

dbi

OdO (!)

dty

dit

dt1

dt2

dCt

“dd” (6)
“Fd” (6)

dOH

dEt

dSt

dE2

dS2

dPO

tcd

Cod

FPt

FSt

DESCRIPTION

COMPRESSOR CONTROLLER (folder with “CP” label)

diFferential. Compressor relay intervention differential; the compressor stops when the
Set point value is reached (as indicated by the control probe), and restarts at tempera-
ture value equal to the Set point plus the value of the differential. 
Note: cannot be 0. 
Higher SEt. Maximum possible set point value. 
Lower SEt. Minimum possible set point value. 
Offset SetPoint. Temperature value to be added algebraically to the set point if reduced
set enabled (Economy function). It can be enabled using a specially configured button. 

Compressor min on time. Minimum compressor activation time before disabling. If set at
0 it is not active. 
Compressor mAx on time. Maximum compressor activation time before disabling. If set at
0 it is not active.

COMPRESSOR PROTECTIONS (folder with “CP” label)

On time (compressor). Compressor activation time in the event of a faulty probe. If set to
“1” with Oft at “0” the controller is always on whereas if Oft >0 it operates in duty cycle
mode. 

See Duty Cycle diagram

OFF time (compressor). Compressor in disabled state time in the event of a faulty probe.
If set to “1” with Oft at “0” the controller is always off whereas if Oft >0 it operates in
duty cycle mode. 

See Duty Cycle diagram

delay (at) On compressor. Delay in activating compressor relay after switch-on of instrument.
delay (after power) OFF. Delay after switch off; the indicated time must elapse between
switch-off of the compressor relay and the subsequent switch-on. 
delay between power-on. Delay between switch-ons; the indicated time must elapse
between two subsequent switch-ons of the compressor. 
delay Output (from power) On. Delay time in activating outputs after switch-on of the
instrument or after a power failure. 0= not active.

DEFROSTING CONTROLLER (folder with “dEF” label) (6)

defrost type. Type of defrost. 
0 = electrical defrosting; 
1 = cycle reversing defrosting (hot gas); 
2 = Free mode defrosting (compressor disabled).

defrost interval time. Period of time elapsing between the start of two defrosting operations.

0= function disabled (defrost is NEVER performed)

defrost time 1. Unit of measurement for defrost times (“dit” parameter). 
0 = “dit” parameter expressed in hours. 
1 = “dit” parameter expressed in minutes. 
2 = “dit” parameter expressed in seconds. 
defrost time 2. Unit of measurement for duration of defrosting (“dEt” parameter). 
0 = “dEt” parameter expressed in hours. 
1 = “dEt” parameter expressed in minutes. 
2 = “dEt” parameter expressed in seconds. 
defrost Counting type. Selection of defrosting time count mode. 
0 = compressor operating hours (DIGIFROST® method); Defrosting active ONLY with
compressor on. 
NOTE: compressor time of operation is counted irrespective of evaporator probe (count-
ing is active if evaporator probe is absent or faulty). The value is ignored if RTC is
enabled. 
1 = equipment operating hours; defrost counting is always active when the machine is on
and starts at each power-on. 
2 = compressor stop. Every time the compressor stops, a defrost cycle is performed
according to the parameter dtY 
3= With RTC. Defrosting at times set by dE1…dE8, F1…F8 
dE1…dE8 parameters daily defrost start time 1…8. Range 0…23, 24= off (default) 
F1…F8 festive defrost start time 1…8. Range 0…23, 24= off (default)

CAUTION: The d1…d8, F1…F8 parameters are only visible if dit=0, dCt=3 with clock
option present. They are included in the dd and Fd folders

defrost Offset Hour. Start of defrost delay time from start-up of instrument. 

defrost Endurance time. Defrosting time-out; determines maximum duration of defrost-
ing. 
defrost Stop temperature. End of defrosting temperature (determined by evaporator
probe). 
defrost Endurance time 2nd evaporator. Defrosting time-out on 2nd evaporator; deter-
mines maximum duration of defrosting on 2

nd

evaporator. 

defrost Stop temperature 2nd evaporator. End of defrosting temperature (determined by
probe on 2nd evaporator). 
defrost (at) Power On. Determines if the instrument must start defrosting at start-up (if
the temperature measured by the evaporator allows this) y = yes, starts defrost at start-
up; n = no, does not start defrost at start-up. 
time compressor for defrost. Minimum time for compressor ON or OFF before defrost If
>0 (positive value) the compressor remains ACTIVE for tcd minutes; If<0 (negative value)
the compressor remains INACTIVE for tcd minutes; If =0 the parameter is ignored.
Compressor off (before defrost). Time for compressor OFF before defrost cycle. If a
defrost cycle is set within the programmed time for this parameter, the compressor is not
started up. If =0 function is stopped.

FAN CONTROLLER (folder with “FAn” label) PLEASE NOTE: this parameter group
always refers to the 1st evaporator

Fan Parameter type. Characterizes the “FSt” parameter that can be expressed as an
absolute temperature value or as a value related to the Set point. 
0 = absolute; 1 = relative. 
Fan Stop temperature. Fan stop temperature; a value read by the evaporator probe that
is higher than the set value causes the fans to stop. The value is positive or negative and,
depending on the FPt parameter, could represent the temperature in absolute value or
relative to Set point.

Tab. 1

Table of parameters

DEFAULT

2.0

50.0

-50.0 

0

0

0

0

1


0

0

0

0

6h

0

1

1

24 
24

0

30min

8.0

30min

8.0

n

10

0

0

2.0

RANGE

0.1...30.0

LSE..302

-55.0...HSE

-30.0...30.0

0...250

0...250

0...250

0...250

0...250
0...250

0...250

0...250

0/1/2

0...250

0/1/2

0/1/2

0/1/2/3

(0=df,

digifrost

1=rt, real

time,

2=SC, stop

compressor

3=RTC)

0...23/0...59
0...23/0...59

0...59

1...250

-50.0... 150

1...250

-50.0... 150

n/y

0...250

-31...31

0/1

-50.0..150.0

VALUE*

LEVEL**

1


1

2

2

2

1

1


1

1

1

1

1

2

2

1


1

1

1

1

1

1

1

2

2

2

1

U.M.

°C/°F

°C/°F 
°C/°F 
°C/°F

min

min

min

min

sec 

min

min

min

num

hours/min/sec

(see dt1)

num

num

num

hours/min
hours/min

min

hours/min/sec

(see dt2)

°C/°F

hours/min/sec

(see dt2)

°C/°F

flag

hours/min/sec

min

min

°C/°F

**PLEASE NOTE: At level 1 the folders will only display all the level 1 parameters. 
At level 2 the folders will only display all the level 2 parameters (in bold type).

Содержание 983LX/CK HACCP

Страница 1: ...t be changed Real Time Clock C CK models By pressing the set button when the rtc label appears the label d00 days is displayed Use the UP and DOWN buttons to set days If you do not use the buttons for...

Страница 2: ...operation is confirmed by pressing the set button If the operation is successful a y is displayed whereas if it is unsuc cessful an n will be displayed Download from reset Connect the copy card with...

Страница 3: ...slave and echo devices The distance between one device and another must be 7 metres maximum whereas the maximum distance between the first and last instrument in the network must be approximately 50m...

Страница 4: ...ther mostat control probe probe1 and or dis play probe probe 3 The temperature limits are defined by the HAL maximum alarm LAL minimum alarm and PbA alarm configuration on probe 1 3 or both parameters...

Страница 5: ...gital outputs MODEL ID 985LX 4 outputs on relays first output A SPDT 8 3 A 250Va second and third output B C SPST 8 3 A 250Va fourth output D SPST 5 2 A 250Va MODEL ID 983LX 2 outputs on relays A SPDT...

Страница 6: ...RTC is enabled 1 equipment operating hours defrost counting is always active when the machine is on and starts at each power on 2 compressor stop Every time the compressor stops a defrost cycle is per...

Страница 7: ...tes alarm External Alarm Lock External alarm to lock controllers n does not lock y locks Alarm Output Polarity Polarity of alarm output 0 alarm active and output disabled 1 alarm active and output ena...

Страница 8: ...ature used by controllers not the temperature displayed that remains unchanged 2 adds to temperature displayed that is also used by controllers Low display Label Minimum value the instrument is able t...

Страница 9: ...output configurability 1 A Same as H21 2 defrost default ID 985LX C CK MODEL ONLY Digital output 3 configurability C Same as H21 3 fans default ID 985LX C CK MODEL ONLY Digital output 4 configurabili...

Страница 10: ...or safety reasons the instrument must be installed and used in accordance with the instructions supplied Users must not be able to access parts with dangerous volt age levels under normal operating co...

Страница 11: ...S CnF Fpr set level 1 par level 1 par level 1 par level 1 par set set set PA2 level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par CP dEF FAn AL set set set...

Страница 12: ...output 1st evaporator A 15 16 N O compressor relay output B 15 17 N O fan relay output C 18 19 N O defrost relay output 2nd evaporator D ID 983LX C CK 1 4 Probe input 3 2nd evaporator 12 13 N O defros...

Отзывы: