background image

PAR.

H21 (!)

H22 (!)

H23 (!)

H24 (!)

(9)

H25 (!)

(3)

H31 (!)

H32 (!)

H33 (!)

H41 
H42
H43

H45

reL 
tAb

UL 
dL
Fr

(1) See Duty Cycle diagram

(2) Positive values: active input when the contact is closed; negative values: active input when contact is open.
(3) Parameter can be seen in models with optional buzzer. 
(4) If the alarms are relative, the parameter HA1 is set to positive values and LA1 to negative values.
(6) In the deF folder there are two folders: “dd” (daily defrost) and “Fd” (Festive Defrost); the first folder includes dE1…dE8 parameters (working day defrost start) and the
second folder includes F1…F8 parameters (Festive defrost) The two folders are only visible if dit =3 and RTC is present. 

NOTE:  DO NOT confuse the days d0...d6

related to the nad folder with dE1...dE8 daily defrost

(7) WARNING! positive or negative values change polarity
(8) Refers exclusively to high and low temperature alarms

(9) Example: configure H24= 9 for dual evaporator function

* VALUE column: to be compiled manually with any custom settings (if different from default value).
** LEVEL column: indicates the visibility level of parameters accessed using a PASSWORD (see relevant paragraph)
**** PA2 is visible (or will be requested, if specified) at level 1 

in the CnF folder 

and can be set (modified) at level 2 

 in the diS folder

(!) WARNING!

• If one or more parameters marked with (!) are modified, the controller must be switched off after the modification and then switched back on

PLEASE NOTE

: We strongly recommend that you switch the instrument off and on again each time parameter configuration is changed in order to prevent malfunction-

ing of the configuration and/or ongoing timings.

folder with “nad” label NIGHT/DAY CONTROL (night and day) FOR /C, /CK MODELS ONLY

folder with “Lin” label LINK CONTROLLER FOR /CK MODELS ONLY

parameters H23-H24  FOR ID 985LX(/C/CK) MODELS ONLY

•The ID 983LX M -  ID 985LX M models do not have a dual evaporator system and therefore do not possess the features and parameters that are specific to
dual evaporators.

DESCRIPTION

(7) WARNING! positive or negative values change polarity Digital output 
configurability 2. (B) 
0 = disabled; 
1 = compressor (default); 
2 = defrost; 
3 = fans; 
4 = alarm; 
5 = auxiliary. 
6 = stand-by 
7 = light 
8 = buzzer. 9 = Defrosting on 2nd evaporator 
Digital output configurability 1. (A) 
Same as H21. (2 = defrost; default)

ID 985LX (/C/CK) MODEL ONLY

Digital output 3 configurability. (C) 

Same as H21. (3 = fans; default)

ID 985LX (/C/CK) MODEL ONLY

Digital output 4 configurability. (D) 

Same as H21. (4 = alarm; default)

PARAMETER VISIBLE IN VERSION WITH BUZZER

Buzzer output configurability. 0 = disabled; 8 = enabled (default) ; 1-7; 9 = not used 
UP button configurability. 
0 = disabled; 
1 = defrosting (default) 
2 = auxiliary; 
3 = reduced set point;
*4 = reset HACCP alarm reset (*only in HACCP models);
*5 = disables HACCP alarms (*only in HACCP models) 
6 = light; 
7 = stand-by; 
8 = maintenance request 
DOWN button configurability. 
Same as H31. (0 = disabled; default) 
ESC button configurability. 
Same as H31. (0 = disabled; default) 
Presence of control probe. n= not present; y= present. 
Presence of Evaporator probe. n= not present; y= present. 
Display probe configuration. n= not present; y= present (display probe); 2EP= present
(probe on 2nd evaporator).

Start of defrosting when two evaporators are used 
0= Defrosting is enabled by controlling that the temperature of the 1st evaporator is
lower than parameter dSt, 
1 = Defrosting is enabled by controlling that at least one of the two probes is below its
end of defrosting temperature (dSt for the 1st evaporator and dS2 for the 2nd evapora-
tor) 
2 =  Defrosting is enabled by controlling that both the probes are below their respective
end of defrosting set points (dSt for the 1st evaporator and dS2 for the 2nd evaporator) 

reLease firmware. Device version: read only parameter. 
tAble of parameters. Reserved: read only parameter.

COPY CARD (folder with “Fpr” label)

Up load. Transfer of programming parameters from instrument to Copy Card. 
Down load. Transfer of programming parameters from Copy Card to instrument. 
Format. Cancels all data entered in the copy card.

N.B.: if “Fr” parameter (copy card formatting) is used, the data entered in the
card will be permanently lost. This operation cannot be undone.

DEFAULT

1

2

3

4 (default) 

9 (dual

evap.) 

8

1

0

0


2EP (dual

evap.) 

1

/
/

/
/
/

RANGE

0...9

0...9

0..9

0...9

0...8

0..8

0...8

0…8

n/y 
n/y 

n/y/2EP

0/1/2

/
/

/
/
/

VALUE*

LEVEL**

2

2

2

2

2

2

2

2



2

2

1
1


1

2

U.M.

num

num

num

num

num

num

num

num

flag 
flag 

num

flag

/
/

/
/
/

ID 983-985 LX (/C /CK) HACCP

9/12

label PA2
In the CnF folder you can access all level 2 parameters from label PA2 by pressing the “set” 
button SEE paragraph 2) Displaying level 2 parameters

(*) In grey the parameters and configurations that meet HACCP minimum requirements.

Содержание 983LX/CK HACCP

Страница 1: ...t be changed Real Time Clock C CK models By pressing the set button when the rtc label appears the label d00 days is displayed Use the UP and DOWN buttons to set days If you do not use the buttons for...

Страница 2: ...operation is confirmed by pressing the set button If the operation is successful a y is displayed whereas if it is unsuc cessful an n will be displayed Download from reset Connect the copy card with...

Страница 3: ...slave and echo devices The distance between one device and another must be 7 metres maximum whereas the maximum distance between the first and last instrument in the network must be approximately 50m...

Страница 4: ...ther mostat control probe probe1 and or dis play probe probe 3 The temperature limits are defined by the HAL maximum alarm LAL minimum alarm and PbA alarm configuration on probe 1 3 or both parameters...

Страница 5: ...gital outputs MODEL ID 985LX 4 outputs on relays first output A SPDT 8 3 A 250Va second and third output B C SPST 8 3 A 250Va fourth output D SPST 5 2 A 250Va MODEL ID 983LX 2 outputs on relays A SPDT...

Страница 6: ...RTC is enabled 1 equipment operating hours defrost counting is always active when the machine is on and starts at each power on 2 compressor stop Every time the compressor stops a defrost cycle is per...

Страница 7: ...tes alarm External Alarm Lock External alarm to lock controllers n does not lock y locks Alarm Output Polarity Polarity of alarm output 0 alarm active and output disabled 1 alarm active and output ena...

Страница 8: ...ature used by controllers not the temperature displayed that remains unchanged 2 adds to temperature displayed that is also used by controllers Low display Label Minimum value the instrument is able t...

Страница 9: ...output configurability 1 A Same as H21 2 defrost default ID 985LX C CK MODEL ONLY Digital output 3 configurability C Same as H21 3 fans default ID 985LX C CK MODEL ONLY Digital output 4 configurabili...

Страница 10: ...or safety reasons the instrument must be installed and used in accordance with the instructions supplied Users must not be able to access parts with dangerous volt age levels under normal operating co...

Страница 11: ...S CnF Fpr set level 1 par level 1 par level 1 par level 1 par set set set PA2 level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par level 2 par CP dEF FAn AL set set set...

Страница 12: ...output 1st evaporator A 15 16 N O compressor relay output B 15 17 N O fan relay output C 18 19 N O defrost relay output 2nd evaporator D ID 983LX C CK 1 4 Probe input 3 2nd evaporator 12 13 N O defros...

Отзывы: