![ELICA Sora Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/elica/sora/sora_use-care-and-installation-manual_2388947005.webp)
5
List of Materials
Removing the packaging
CAUTION!
Remove carton carefully, wear gloves to protect against sharp edges.
WARNING!
Remove the protective film covering the product before putting into
operation.
Parts supplied
•
Hood canopy
assembly with blower.
•
Lamps already installed.
•
Transition with damper
(3
1
⁄4
”
x 10” rectangular)
• Grease filter.
•
Hardware bag with:
•
Use, care and installation guide
• 4 - 4x8 mm screws (to assemble Transition)
• 6 - 4.5x13 mm screws
• 4 - 5x4.5 mm screws
• 4 - 10 x 50 mm wall anchors
•
T20 TORX®† adapter
Tools/Materials required
•
Wire nuts
•
Metal
duct lenght to suit installation
•
1
⁄2
”
Romex wire connector
•
Measuring tape
•
Pliers
•
Gloves
•
Knife
•
Safety glasses
•
Electric drill with
5
⁄16
” and
3
⁄8
” Bits
•
Spirit level
•
Duct tape
•
Screw drivers
•
Philips (Posidrive #2)
• Torx #2
•
Wire cutter/ stripper
•
Masking tape
•
Hammer
•
Saw, jigsaw or reciprocating saw
Product Dimensions
29
1
⁄
8
” (74 cm)
35
1
⁄
8
” (89.2 cm)
2
9
⁄
16
”
(6.5 cm)
3
⁄
8
”
(1 cm)
12”
(30.5 cm)
10”
(25.4 cm)
23”
(58.4 cm)
30” (76.2 cm)
36” (91.4 cm)
2”
(5.1 cm)
7
1
⁄
2
”
(19.0 cm)
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances. Have a
qualified technician install the range hood. It is the installer’s respon
-
sibility to comply with installation clearances specified on the model/
serial rating plate. The model/serial rating plate is located behind the
left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such
as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) installation see the installation in-
structions in this guide. Recirculation Kit is available from your dealer
or an authorized parts distributor. All openings in ceiling and wall
where canopy hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home Con-
struction and Safety, Title 24, HUD, Part 280) or when such standard
is not applicable, the standard for Manufactured Home Installation
1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A, or latest edition, or with local codes.
†®TORX is a registered trademark of Saturn Fasteners, Inc.
Содержание Sora
Страница 32: ...LIB0104431A Ed 01 15 Printed in Mexico...