Water Main Shut-Off Advanced User Manual
LED & Button Behavior
Page 12
LED & Button Behavior
Color
Behavior
This happens when…
Blue
Blink Continuously
…the device is not yet included in a Z-Wave Net-
work.
On Continuously
…the device is included in a Z-Wave Network and is
in the “Closed” position.
Off Continuously
…the device isincluded in a Z-Wave Network and is
in the “Open” position.
Table 2 - LED Blinking Behavior
Action
Condition
Result
Push Button Once
All Conditions
Open or Close Valve
Push
OPEN/CLOSE BUTTON
3 Times
Water Main Shut-Off
Already Included in System
Device sends node info to Group 1
Water Main Shut-Off
Already Included in
System and Controller is in
Exclusion Mode
Device is excluded from the z-Wave Network
On/Off Plug Not Yet
Included in System
Device enters inclusion mode
Press and Hold for
10+ seconds
All conditions
Device will be reset to factory settings, and a
DEVICE_RESET_LOCALLY command will be sent to
Node 1
Table 3 - Button Behavior