Water Main Shut-Off Advanced User Manual
LED & Button Behavior
Page 14
Command Class
Notes
Association V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold five devices. The
Water Main Shut-Off sends this group a Binary Switch Report whenever
it is turned on or off. The Water Main Shut-Off also sends this group a
Device Reset Locally notification to remove itself from the Z-Wave net-
work.
Binary Switch V1 (25)
Binary Switch commands will open and close the Water Main Shut-Off.
Binary Switch Report commands are also used to communicate changes
in device status (e.g. the Valve opening/closing) to the controller. See
below for Binary Switch status values and their corresponding meaning
within the Shut-Off:
Valve Open: FF
Valve Closed: 00
Table 5 - Command Classes Continued