board functions and layout
6
© ELETTROQUADRI S.r.l.
55 / 66
INSTALLATION MANUAL
Connector J8
I – 1
S+
Up travel control signal positive
U – 2
S-
Up travel control signal negative
U – 3
D-
Down travel control signal negative
I – 4
D+
Down travel control signal positive
I – 5
GV+
High speed control signal positive
U – 6
GV-
High speed control signal negative
U – 7
PV-
Low speed control signal negative
I – 8
PV+
Low speed control signal positive
Connector J11
I – 1
FSC
High and low speed control
I – 2
UD
Up and down travel control
I – 3
DRA
Front door / rear door open enable zone control with variable speed
drive in emergency (SEB reed switch)
I – 4
DRB
Rear door / front door open enable zone control
with variable speed drive in emergency (SEA reed switch)
I – 5
CCS
Safety circuit control with hydraulics / contactors (TL1 and TL2)
with variable speed drive
I – 6
RM
Maintenance manoeuvre
I – 7
DMS
Up travel minimum distance reed switch
I – 8
DMD
Down travel minimum distance reed switch
Connector J12
I – 1
FRM
Fire services manoeuvre
I – 2
CF4
Programmable (RA reed switch – travel between short floors – distance
< 400mm)
I – 3
CF5
Programmable (RB reed switch – travel between short floors – distance
< 400mm)
I – 4
CF1
Programmable (enable full emergency manoeuvre from cabinet with
variable speed drive or hydraulics)
I – 5
CF2
-
I – 6
CF3
-
M2A top terminal block
I – 1
TP
Motor thermistor control
I – 2
UM
Up travel reed switch
I – 3
DM
Down travel reed switch
M2B top terminal block
I – 1
-
-
I – 2
-
-
I – 3
OVLD
overload / overtemperature in the machine room