Programming
4
© ELETTROQUADRI S.r.l.
33 / 66
INSTALLATION MANUAL
4.5.3.
Fo selection - Omnibus procedure
Press
ENT/RST
to access the
Fo
function, then close the automatic valve
VA
.
Sequence of operations
0
the car starts moving up and down
1
if any calls are made, they are handled in the normal manner
2
once the limit of 50 is reached, the process terminates
4.5.4.
Ec selection - manual car movement (overtravel test)
Test procedure to be run at on completion of programming.
Sequence of operations
0
the display shows a flashing
Ec
1
close the automatic valve
VA
2
use the DW button to travel down or the UP button to travel up
3
at the end, open the automatic valve
VA
4
the procedure terminates after 2 seconds
5
close the automatic valve
VA
4.5.5.
In selection - uncontrolled movement test
Sequence of operations
0
the display shows a flashing
In
1
close the automatic valve
VA
2
the door opens automatically
3
use the DW button to travel down or the UP button to travel up
4
at the end, open the automatic valve
VA
5
the procedure terminates after 2 seconds
6
close the automatic valve
VA
MP3