background image

DIODE CHECK

RANGE

RESOLUTION

MAX TEST CURRENT

MAX OPEN CIRCUIT VOLTAGE

DIODE

1mV

1.4mA

2.8V

TRANSISTOR h

FE

TEST

RANGE

TEST RANGE

TEST CURRENT

TEST VOLTAGE

NPN/PNP

0 - 1000

Ib = 10

µ

A

Vce  3V

-15-

SPECIFICATIONS

GENERAL

DISPLAY

3 1/2 digit LCD, with polarity

OVERRANGE INDICATION

3 least significant digits blanked.

MAXIMUM COMMON MODE
VOLTAGE

500V peak.

STORAGE ENVIRONMENT

–15

O

C to 50

O

C.

TEMPERATURE COEFFICIENT

(0

O

C to 18

O

C and 28

O

C to 50

O

C)

less than 0.1 x applicable accuracy
specification per 

O

C.

POWER

9V alkaline or carbon zinc battery.

DIMENSIONS

128 x 75 x 24mm.

DC VOLTAGE

RANGE

RESOLUTION

ACCURACY

200mV

0.1mV

+0.5%  rdg + 2d

2000mV

1mV

+0.5%  rdg + 2d

20V

10mV

+0.5%  rdg + 2d

200V

100mV

+0.5%  rdg + 2d

1000V

1V

+0.5%  rdg + 2d

MAXIMUM ALLOWABLE INPUT

1000VDC or peak AC.

INPUT IMPEDANCE

1M

.

DC CURRENT

RANGE

RESOLUTION

ACCURACY

200

µ

A

0.1

µ

A

+1%  rdg + 2d

2000

µ

A

1

µ

A

+1%  rdg + 2d

20mA

10

µ

A

+1%  rdg + 2d

200mA

100

µ

A

+1.2%  rdg + 2d

10A

10mA

+2%  rdg + 3d

OVERLOAD PROTECTION

.25A/250V fuse  (mA input only).

AC VOLTAGE

RANGE

RESOLUTION

ACCURACY

200V

100mV

+1.2%  rdg + 10d

750V

1V

+1.2%  rdg + 10d

MAXIMUM ALLOWABLE INPUT

750Vrms.

FREQUENCY

45 - 450Hz.

RESISTANCE

RANGE

RESOLUTION

ACCURACY

200

0.1

+0.8%  rdg + 2d

2000

1

+0.8%  rdg + 2d

20k

10

+0.8%  rdg + 2d

200k

100

+0.8%  rdg + 2d

2000k

1k

+1%  rdg + 2d

MAXIMUM OPEN CIRCUIT VOLTAGE

2.8V.

RESISTANCE MEASUREMENT

Figure 7 shows a simplified diagram of the resistance measurement
function. A simple series circuit is formed by the voltage source, a
reference resistor from the voltage divider (selected by the selector
switches), and the test (unknown) resistor. The ratio of the two resistors
is equal to the ratio of their respective voltage drops. Therefore, since
the value of one resistor is known, the value of the second can be
determined by using the voltage drop across the known resistor as a
reference. This determination is made directly by the A/D converter.

Overall operation of the A/D converter during a resistance
measurement is basically as described earlier with one exception. The
reference voltage present during a voltage measurement is replaced by
the voltage drop across the reference resistor. This allows the voltage
across the unknown resistor to be read during the read period.

h

FE

MEASUREMENT

Figure 8 shows a simplified diagram of the h

FE

measurement function.

Internal circuits in the 7106 IC maintain the COMMON line at 2.8 volts
below V+. When a PNP transistor is plugged into the transistor socket,
base to emitter current flows through resistor R10. The voltage drop in
resistor R10 due to the collector current is fed to the 7106 and indicates
the h

FE

of the transistor. For an NPN transistor, the emitter current

through R11 indicates the h

FE

of the transistor.

Figure 7

Simplified Resistance Measurement Diagram

900k

Test
Resistor

100

900

2000

/Dio

200

7106

Reference

Voltage

Low Pass

Filter

Voltage

Source

Common

90k

9k

2000k

20k

200k

Figure 8

R10

220k

Common

R23
10

R11

220k

PNP

NPN

7106

100mV

Ref.

Low Pass

Filter

V+

E

C

C

E

B

B

Содержание M-1006K

Страница 1: ...DIGITAL MULTIMETER KIT MODEL M 1006K Assembly and Instruction Manual Elenco Electronics Inc Copyright 2001 Elenco Electronics Inc 753096...

Страница 2: ...ld 162200 1 R2 352k 5 1 2W orange green red orange green 163551 5 R18 R22 470k 5 1 4W yellow violet yellow gold 164700 1 R1 548k 5 1 2W green yellow gray orange green 165451 1 R23 1M 5 1 4W brown blac...

Страница 3: ...nit 1 000 nano units 1 micro unit 1 000 milli units 1 unit 1 000 kilo units 1 kilo unit METRIC UNITS AND CONVERSIONS IDENTIFYING CAPACITOR VALUES Capacitors will be identified by their capacitance val...

Страница 4: ...Component Lead Solder Soldering Iron Drag Foil 1 Solder all components from the copper foil side only Push the soldering iron tip against both the lead and the circuit board foil 2 Apply a small amou...

Страница 5: ...W Resistor white brown black black brown see Figure A R14 4 7k 5 1 4W Resistor yellow violet red gold see Figure A R13 100 5 1 4W Resistor brown black brown gold see Figure A R19 470k 5 1 4W Resistor...

Страница 6: ...e component side as shown in Figure D Adjust the wire so that it sticks out the other solder side of the PC board 3 16 of an inch Solder the wire to the PC board on the component side only Be sure tha...

Страница 7: ...ver backing Place the LCD zebra frame and zebras into the top case as shown in Figure E Be sure that the LCD tab is in the same direction as shown in the figure Cut open the plastic envelope containin...

Страница 8: ...Place the PC board over the selector knob Be sure that the 8 pin socket slides into its hole Then fasten the PC board with two 6mm screws as shown in Figure G Insert the 0 25A 250V fuse into the fuse...

Страница 9: ...t wire so that there is less wire between the 10A DC and COM sockets If the meter reads low resolder the shunt wire so that there is more wire between the sockets 1 ACV Range 750 0 0 0 200 0 0 0 2 DCA...

Страница 10: ...e following table Read the currents shown and compare to a known accurate meter If any of the above tests fail a Check the fuse b Check the value and soldering of resistors R7 R8 and R9 DC VOLTS TEST...

Страница 11: ...ring of resistors R1 R6 and R12 hFE 1 Set the range switch to hFE and insert a small transistor into the appropriate NPN or PNP holes in the transistor socket 2 Read the hFE of the transistor The hFE...

Страница 12: ...t is clocked at about two readings per second The digitized measurements are presented to the display as four decoded digits seven segments plus polarity The decimal point position on the display is d...

Страница 13: ...switch closes This applies a known reference voltage to the input to the A D converter The polarity of this voltage is automatically selected to be opposite that of the unknown input voltage thus cau...

Страница 14: ...erters One inverter shown for clarity 7 6 4 OSC 1 OSC 2 OSC 3 DIGITAL SECTION ANALOG SECTION of 7106 CREF RINT CAZ CINT INT CREF REF HI REF LO CREF BUFFER V 35 42 44 43 41 36 37 1 AUTO ZERO A Z Z1 A Z...

Страница 15: ...alue required to give the correct RMS reading CURRENT MEASUREMENT Figure 6 shows a simplified diagram of the current measurement function Internal shunt resistors convert the current to between 0 199...

Страница 16: ...mple series circuit is formed by the voltage source a reference resistor from the voltage divider selected by the selector switches and the test unknown resistor The ratio of the two resistors is equa...

Страница 17: ...t known set the switch to the highest range 4 Connect the leads across the points to be measured and read the display If the range switch is too high reduce it until a satisfactory reading is obtained...

Страница 18: ...lay it indicates that the battery should be replaced To replace battery and fuse 250mA 250V remove the 2 screws in the bottom of the case Simply remove the old fuse battery and replace with a new fuse...

Страница 19: ...18 SCHEMATIC DIAGRAM...

Страница 20: ...Elenco Electronics Inc 150 W Carpenter Avenue Wheeling IL 60090 847 541 3800 www elenco com e mail elenco elenco com...

Отзывы: