background image

LCD Display

1.  

Manual Range

  Indicator of manual range

2.  

Warning 

! 

      Indicator for Warning signal

3. 

            The battery is low

4. 

            Indicator for high voltage signal

5. 

            Indicator for Negative reading 

                              display

6.        

AC

               Indicator for AC voltage or current

                               ( DC indicator do not display)

7. 

            Data hold is active

8. 

            Test of diode

9. 

            The continuity buzzer is on

10.   Number          Indicates testing reading

11. Units of measurement:

General Specifications

1. Maximum Voltage between terminal input and 

COM: 1000V( except 200mV, 250V)

2. 

μ

A  mA terminal input protection: (CE)250mA 265V 

auto recovery fuse

3.  10A  terminal  input  protection:  (CE)F1  (10A  H 

1000V) Fast type melted fuse Φ10.3x38mm

4.  Resistance input protection: PTC/1000V

5.  Capacitance input protection:  (CE)F2, F3 (0.5A H 

1000V) Fast type melted fuse Φ6.35x31.8mm

6.  Frequency input protection: PTC/1000V

7.  Temperature input protection:  (CE)0.5A 1000V 

fuse

8.           terminal input protection: PTC/1000V

9.  hFE input protection:  (CE)250mA 265V auto 

recovery fuse, F3 (0.5A H 1000V) Fast type melted 

fuse Φ6.35x31.8mm

10.  Display:  LCD  full  function  signal  display, 

maximum reading is 1999(UT801) , 19999(UT802)

Updates 2-3 times / second

11.  Range: Manual

12.  Polarity Display:  Auto

13.  Overload indication: 1

14.  Battery Deficiency:   

15.  Operating Temperature: 0

40

(32

℉~

104

)

16.  Storing Temperature: -10

50

(14

℉~

122

)

17.  Relative Humidity:  0

℃~

30

 below  ≤75%

                                      30

℃~

40

℃ 

≤50%

18.  Electromagnetic Field: Under 1V/m the 

influence 

of radiated radio-frequency electromagnetic field 

phenomenon, Total accuracy= specific a 

measurement  5

%

,  Over  1V/m  radiated  radio-

frequency electromagnetic which do not have any 

reference data on this topic.

19.  Power: AC(external power adapter AC220V/

DC9V-200mA) or DC(internal battery type 2 R14/1.5V 

6 pieces)

20.  Product size: (300x245x105)mm

21. Product Net Weight :  About1500g(without the 

accessories)             

22.  Safety Compaliances : IEC 61010: CAT

1000V

6.  Do not overload voltage or current on EITHER 

between terminal and terminal OR between terminal 

and grounding which indicate on meter limitation.

7.  The rotary switch should be placed in the right 

position and no any changeover of range shall be 

made during measurement is conducted to prevent 

damage of the Meter.

8.  Do not use or store the meter in an environment 

of  high  temperature,  humidity,  flammable  and 

electromagnetic environment.  The performance of 

the meter may deteriorate after dampened.

9.   The  internal  circuit  of  the  meter  shall  not  be 

altered at will to avoid damage of the meter and any 

accident

10.    Replace  the  battery  as  soon  as  the  battery 

indicator “       ”Appears.  With a low battery, the 

meter might produce false readings that can lead to 

electric shock and personal injury.

11.  Turn the meter off when it is not is use and take 

out the battery when not using for a long time.

UT801/802 

Operating Manual

Bench Type Digital Multimeters 

UT801/802 

Operating Manual

Overview

     Digital Bench-Type Multimeter Model UT801 is the 

maximum reading 1999 and 3 1/2 digits and UT802 

is  the  maximum  reading  19999  and  4  1/2  digits, 

both models are in manual range, DC / AC current 

type digital multimeter, This is also the extra large 

characters in LCD display backlight with full function, 

full measurement and full overload protection as well 

as a good product design outlook, In addition to all 

the conventional features include DC/AC voltage, 

DC/AC current, resistance, frequency, capacitance, 

temperature 

,  Transistor  hFE

diode  and 

continuity buzzer.

     This operating manual covers information on 

safety  and  cautions.    Please  read  the  relevant 

information carefully and observe all the Warnings 

and Notes strictly.

Unpacking Inspection

      Open the package case and take out the Meter. 

Check the following items carefully to see any missing 

or damaged part.  If you 

find

 any missing or damage, 

please contact your dealer in your country.

 ●  Operating Manual                             1 piece

 ● 

 Test Lead                                          1 pair

 ● 

 Alligator Clip                                      1 pair

 ●  K

 Type Temperature Probe               1 piece

     ( For the temperature under 230

testing)      

 ●  Multi-Purpose Socket

 

        1 piece

 ●  Power Cord                                       1 piece  

     (AC220V 50Hz DC9V/200mA)   

                     

Safety Information

          This  Meter  complies  with  the  standards 

IEC61010-1  in  pollution  degree  2,  overvoltage 

category (CAT II 1000V) and double insulation. If you 

can not follow up this operating instruction to use the 

meter and it reduces the chance to have an using 

protection.

1.  Before using the Meter and Test Leads inspect 

both items.  Do not use the Meter and Test Leads 

if it is damaged or the case (or part of the case) is 

removed or no reaction on LCD display. Prohibited 

to use the meter without housing or housing without 

screw 

fix

 up in order to avoid possible electric shock 

or to avoid possible damage to the meter or to the 

equipment under test.

2.  If the damage of test leads, use only the same 

model number or identical electrical specifications 

replacement parts.

3.  Do not use your finger to touch on any testing 

cable, connector, unused terminal input or circuit 

during the testing stage

.

4.  When the meter working at an effective voltage 

over 60V in DC or 30V rms in AC, special care should 

be taken for there is danger of electric shock.

5.  Selecting the correct terminal input and turn the 

rotary switch to select the measuring function.  In 

case of no any idea on the value input of the current, 

just simply test from the high value to low one.

Unit of Voltage: The millivolt, volt
Unit of current: Microampere, milliampere, 
ampere
Unit of electrical resistance: Ohm, thousand 
ohms, trillion ohm
Unit of electrical capacity: Accepts the farad, 
the microfarad

Unit of Frequency: Kilohertz

Unit of Temperature: Degree Celsius Factor 
Unit of Triode enlargement: Times

 

 

V

 

,

V

m

μA, mA

,

 A 

Ω, kΩ, 

M

Ω

nF/

μF 

k

Hz


β

Operational Measurement Guide

 (see Diagram 1, 2, 

3)

Diagram 1

Diagram 2

Diagram 3

Functions

 Symbol   Terminal Input 

            Explanation

   V          V 

←→

 COM  DC Voltage Measurement

   V          V 

←→

 COM  AC Voltage Measurement

   Ω          V 

←→

 COM  Resistance Measurement

                V 

←→

 COM  Diode / Continuity Buzzer 

                                     Measurement
  kHz       V 

←→

 COM  Frequency Measurement

  A    

       

mA

 μ

A

 ←→ COM

 

mA/μ

A DC Current Measurement

             10A 

←→ 

COM 

ADC

 

Current Measurement

   A        

mA

 μ

A

 ←→ COM

 

mA/μ

A AC Current Measurement

              10A

 ←→ 

COM 

A AC Current Measurement

   F          V

←→

 mA

 μ

A   

Capacitance Measurement

    

(Use Multi-Purpose Socket)

 

             V 

←→

 mA

 μA

 

Temperature Measurement

      (Use Multi-Purpose Socket)

   hFE   V 

←→

mA

 μA

  Triode Enlargement Factor

    

(Use Multi-Purpose Socket)

  Measurement

 

Functional Buttons

                Turn the power on and off Turn the display 

                backlight on and off(suitable for battery 

                supply, backlight turn on about 10 seconds 

                after auto  shut down.)

             

   Press Hold to enter and exit the hold  mode 

                in any mode, the meter beeps.

 

LIGHT 

HOLD

Reviews: