background image

AC VOLTS TEST

To test the ACV ranges, we will need a source of AC voltage. The AC power line is the most convenient.

CAUTION: Be very careful when working with 120VAC. Be sure that the range switch is in the 200 or 750VAC
position before connecting the test leads to 120VAC.

1) Set the range to 200VAC and measure the AC power line. The voltage should be about 120VAC. Compare

the reading to a meter of known accuracy.

2) Set the range to 750VAC and measure the AC power line. The voltage should be about 120VAC. Compare

the reading to a meter of known accuracy.

If either if the above tests fail:

a)   Check the values and the soldering of resistors R1 - R6, R22.

b)   Check that diode D1 is mounted as shown in the assembly instructions.

DC AMPS TEST

1) Set the range switch to 200

µ

A and connect the meter as in Figure J. With R

A

equal to 100k

the current

should be about 90

µ

A. Compare the reading to a known accurate meter.

2) Set the range switch and R

A

as in the following table. Read the currents shown and compare to a known

accurate meter.

If any of the above tests fail:
a) Check the fuse.
b) Check the value and soldering of resistors R7, R8, and R9.

DC VOLTS TEST

1) If you have a variable power supply, set the supply to about the midpoint of each of the DCV ranges and compare the

kit meter reading to a meter known accuracy.

2) If you do not have a variable power supply, make the following two tests:

a)

Set the range switch to 2000mV and measure the voltage across the 100 ohm resistor of Figure Ia. You should get
about 820mV. Compare the reading to a meter of known accuracy.

b)

Set the range switch to 200mV and measure the voltage across the 100 ohm resistor of Figure Ib. You should get
about 90mV. Compare the reading to a meter of known accuracy.

If any of these tests fail:

a) Recheck the meter

calibration.

b) Check the value and the

soldering of resistors R1-
R6, R12-R17, R21-R24,
and capacitor C3.

-9-

Figure J

Figure Ia

Figure Ib

1k

10A DC

V

mA

COM

100

9V

123

10k

10A DC

V

mA

COM

100

9V

123

Range Switch

R

A

Current (approx.)

2000

µ

A

10k

900

µ

A

20mA

1k

9mA

200mA

470

19mA

V

mA

COM

10A DC

123

Accurate

Meter

R

A

9V

Содержание M-1006K

Страница 1: ...DIGITAL MULTIMETER KIT MODEL M 1006K Assembly and Instruction Manual Elenco Electronics Inc Copyright 2001 Elenco Electronics Inc 753096...

Страница 2: ...ld 162200 1 R2 352k 5 1 2W orange green red orange green 163551 5 R18 R22 470k 5 1 4W yellow violet yellow gold 164700 1 R1 548k 5 1 2W green yellow gray orange green 165451 1 R23 1M 5 1 4W brown blac...

Страница 3: ...nit 1 000 nano units 1 micro unit 1 000 milli units 1 unit 1 000 kilo units 1 kilo unit METRIC UNITS AND CONVERSIONS IDENTIFYING CAPACITOR VALUES Capacitors will be identified by their capacitance val...

Страница 4: ...Component Lead Solder Soldering Iron Drag Foil 1 Solder all components from the copper foil side only Push the soldering iron tip against both the lead and the circuit board foil 2 Apply a small amou...

Страница 5: ...W Resistor white brown black black brown see Figure A R14 4 7k 5 1 4W Resistor yellow violet red gold see Figure A R13 100 5 1 4W Resistor brown black brown gold see Figure A R19 470k 5 1 4W Resistor...

Страница 6: ...e component side as shown in Figure D Adjust the wire so that it sticks out the other solder side of the PC board 3 16 of an inch Solder the wire to the PC board on the component side only Be sure tha...

Страница 7: ...ver backing Place the LCD zebra frame and zebras into the top case as shown in Figure E Be sure that the LCD tab is in the same direction as shown in the figure Cut open the plastic envelope containin...

Страница 8: ...Place the PC board over the selector knob Be sure that the 8 pin socket slides into its hole Then fasten the PC board with two 6mm screws as shown in Figure G Insert the 0 25A 250V fuse into the fuse...

Страница 9: ...t wire so that there is less wire between the 10A DC and COM sockets If the meter reads low resolder the shunt wire so that there is more wire between the sockets 1 ACV Range 750 0 0 0 200 0 0 0 2 DCA...

Страница 10: ...e following table Read the currents shown and compare to a known accurate meter If any of the above tests fail a Check the fuse b Check the value and soldering of resistors R7 R8 and R9 DC VOLTS TEST...

Страница 11: ...ring of resistors R1 R6 and R12 hFE 1 Set the range switch to hFE and insert a small transistor into the appropriate NPN or PNP holes in the transistor socket 2 Read the hFE of the transistor The hFE...

Страница 12: ...t is clocked at about two readings per second The digitized measurements are presented to the display as four decoded digits seven segments plus polarity The decimal point position on the display is d...

Страница 13: ...switch closes This applies a known reference voltage to the input to the A D converter The polarity of this voltage is automatically selected to be opposite that of the unknown input voltage thus cau...

Страница 14: ...erters One inverter shown for clarity 7 6 4 OSC 1 OSC 2 OSC 3 DIGITAL SECTION ANALOG SECTION of 7106 CREF RINT CAZ CINT INT CREF REF HI REF LO CREF BUFFER V 35 42 44 43 41 36 37 1 AUTO ZERO A Z Z1 A Z...

Страница 15: ...alue required to give the correct RMS reading CURRENT MEASUREMENT Figure 6 shows a simplified diagram of the current measurement function Internal shunt resistors convert the current to between 0 199...

Страница 16: ...mple series circuit is formed by the voltage source a reference resistor from the voltage divider selected by the selector switches and the test unknown resistor The ratio of the two resistors is equa...

Страница 17: ...t known set the switch to the highest range 4 Connect the leads across the points to be measured and read the display If the range switch is too high reduce it until a satisfactory reading is obtained...

Страница 18: ...lay it indicates that the battery should be replaced To replace battery and fuse 250mA 250V remove the 2 screws in the bottom of the case Simply remove the old fuse battery and replace with a new fuse...

Страница 19: ...18 SCHEMATIC DIAGRAM...

Страница 20: ...Elenco Electronics Inc 150 W Carpenter Avenue Wheeling IL 60090 847 541 3800 www elenco com e mail elenco elenco com...

Отзывы: