PSI 9000 15U/24U Series
IF Level 1
Level 2 Level 3
Description
Ethernet / ModBus-TCP
, 1 & 2 Port
IP Settings 1
DHCP
The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then
network parameters will be set as defined in item “Manual”
Manual IP address
This option is activated by default. An IP address can be manu
-
ally allocated.
Gateway
Here a gateway address can be allocated if required..
Subnet mask
Here a subnet mask can be defined if the default subnet mask
is not suitable.
DNS address 1
DNS address 2
Here the addresses of the first and second Domain Name Serv
-
ers (DNS) can be defined, if needed.
Port
Range: 0...65535. Default ports:
5025
= Modbus RTU (all Ethernet interfaces)
Reserved ports which must not be set with this parameter:
502
= Modbus TCP (Modbus-TCP interface only)
other typical reserved ports
IP Settings 2-P1
IP Settings 2-P2
AUTO
Settings for the Ethernet port such as transmission speed are
set automatically.
Manual Half duplex
Manual selection for transmission speed (10MBit/100MBit) and
duplex mode (full/half). It is recommended to use the “AUTO”
option and only revert to “Manual” if these parameters fail.
Full duplex
10MBit
100MBit
Host name
Free choice of host name (default: Client)
Domain name
Free choice of Domain (default: Workgroup)
TCP Keep-Alive Enable TCP keep-alive
IF Level 1
Description
Profinet/IO, 1 & 2 Port
Function Tag
String input box for a user-definable text which describes the Profinet slave function tag.
Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profinet slave location tag.
Max. length: 22 characters
Station Name
String input box for a user-definable text which describes the Profinet station name. Max.
length: 54 characters
Description
String input box for a user-definable text which describes the Profibus slave. Max.
length: 54 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave installation
date tag. Max. length: 40 characters
IF Level 1
Description
Profibus DP
Node Address
Selection of the Profibus or node address of the device within range 1...125 via direct input
Function Tag
String input box for a user-definable text which describes the Profibus slave function tag.
Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profibus slave location tag.
Max. length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave installation
date tag. Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters