background image

MANUAL CODE: XXXXX 

PROFESSIONAL SOUS COOKER 

 

ISSUE DATE: 15/01/2018  vers_00_05

 

Rev.  00.00   WITH REFERENCE TO FIRMWARE VERSION :00_15 and more  

 

 

ELE

GEN

 

by Quaglia Luigi  - Via Jmre Nagy  8-8/A 42019 - Scandiano Reggio Emilia Italy- VAT No. 02018620357 

TEL.+390522859721 – FAX +390522767677 - 

VOIP Skype. eleg2002 

- Web-www.elegen.it - emai

[email protected] 

 

 

Page  10  of 16 

 

7.2  WATER LEVEL CONTROL    

The water level should be between the maximum and minimum level indicated on the frame of the machine, a lower level is not 
accepted and the machine will block, for the low level.    

 

7.3  HOLD FUNCTION   

 

The  Hold  function  is  an  innovative  function  to  avoid  proliferation  of  bacterial  load  on  the  product  at  the  end  of  the  cooking 
cycle. At the end of cooking, if you do not intervene to switch off the SOUS COOKER within approx. 5 minutes from when the 
cycle end warning is given, the control passes to the HOLD function and the temperature is automatically brought to 66°C, to 
avoid proliferation of bacteria on the product.   
This  function  is  active  by  default,  but  you  can  disable  it  as  you  wish,  to  enable  or  disable  the  HOLD  function,  proceed  as 
follows: 

1)

 

Press the Setting key   

2)

 

The writing –HOLDFN ON- is displayed 

3)

 

With the + and - keys of the probe dial at the heart select the desired option –HOLDFN ON- (enabled) HOLDFN OFF 

(disabled)  

4)

 

Press the OK key to confirm  

Press the ESC key to exit the setting menu, or press the Setting key to continue with the settings.   

 

 

 

7.4 SETTING KEY PROGRAMMING    

You can program some parameters using the Setting menu, push 

Setting

 button  to enter on it, every function is accessed by 

pushing the button   
The parameters that can vary are as follows:  

1)

 

 Preheating function programming: PrHEAT OFF. See dedicated section for setting 7.7 

 

2)

 

Start the cycle in automatic Count Down mode; 

Auto Start, 

from this position you can program an end time based on 

which SOUS COOKER starts the work cycle according to the previously selected program, you need to leave SOUS 
COOKER switched ON. 

 

 

 

3)

 

Limescale function (descaling), with this function it is activated the cleaning of the limestone that is deposited on resin 

and on the immersed parts. To activate the function, press the button Place a sous cooker in a tank  with water and 
vinegar and start the decalcification function.  

 

4)

 

Hold Function (HOLDFN xxx message); xxx = on- ; off ; enabled or disabled 

HOLD

 function (see paragraph relating 

to this function section 

7.3

 ), by default the function is enabled.  

 

5)

 

Activation the probe at the heart (HEARTP xxx message); xxx = on- ; off; enables or disables the temperature at the 

heart probe reading, by Default it is enabled, but it is automatically bypassed in the absence of the probe.  

 

6)

 

Filter 50/60Hz, important for greater reading precision based on the mains frequency 50 / 60hz. (FILtEr xxx message): 

xxx = 50H- ; 60H; Change filter trail activation at 50 and 60 Hz, by default 50Hz, in the zones where there is a mains 
frequency of 60Hz, you should enable the filter at 60Hz for greater reading precision of the temperature.  

 

7)

 

Reserved (COrreS xxx message); reserved parameter, use of this parameter is not recommended.  

 

To access the setting of one of these parameters, Sous Cooker must  be on the main mask. 
       1)    Press the Setting key 
       2)    The first parameter will be displayed 
       3) Press  OK button to select the function with the Setting key and move to the next function, 
This menu is sequential type and at the end of the selectable parameters it goes out and returns to the main mask. 

 

Once  the  desired  function  has  been  selected  to  change  a  parameter,  use  the  +  and  -  keys  of  the  dial  for  the  parameter  and 
confirm with the OK key. To start the function, press the OK button. 

 

Once the desired function has been selected to cancel it, press 

STOP/START/ESC

 until you return to the main screen. 

 

When the Auto Start function is selected after a few minutes, a sequence of minus signs is displayed, the minus sign running on 
the  display  and  indicating  the  correct  operation,  a  few  minutes  before  the  automatic  switch  on,  the  display  is  restarted  and 
indicating the remaining time at startup. 

 

Attention!! in countries with a frequency of 60Hz, you need to set the parameter on FILtEr 60H, vice versa in countries 
with a frequency of 50Hz, you need to set the parameter on FILtEr 50H (default value).   

 

7.5 FN KEY SPECIAL FUNCTIONS   ( only professional )  

 

Pressing the FN key, you can access some special functions inside the system, pressing this key, the led lights up for the 

fn on

 

key, to indicate the function is on. You can thereby access the following functions  

1)

 

Displays the real temperature both of the tank and the probe at the heart, without heating; 

LIVE

,  

from this position, you can display the temperature both of the tank and the probe at the heart, to monitor the 
temperatures.  

2)

 

Adjustment of the circulator in manual mode without heating, with the real temperature display, both of the tank and 

the probe at the heart; 

CIRCULATOR

, from this position you can enable and display the temperatures both of the 

tank and the probe at the heart, without heating being enabled.

 

You can vary the speed of the circulator to a desired 

value between 5 and 10, 10 is the maximum value, 5 is the minimum value. In this function, it can be used as a simple 

Содержание SOUS COOKER PRO CHEF

Страница 1: ...email elegen elegen it Page 1 of 16 Operating use and maintenance manual SOUS COOKER PRO CHEF SOUS COOKER PROFESSIONAL Low temperature immersion cooking system ATTENTION This manual contains all the...

Страница 2: ..._____________________________________ 7 5 0 DESCRIPTION OF THE CONTROL PANEL _______________________________________________________________ 8 6 0 INSTALLATION_________________________________________...

Страница 3: ...y law to diffuse or duplicate totally or partially the images and information contained in this manual without the manufacturer s prior authorisation The manufacturer is the owner of the rights to thi...

Страница 4: ...tly prohibited The fuse is a protection element that is essential to proper machine operation and in preventing damage to persons or property Always disconnect the mains before carrying out the operat...

Страница 5: ...machine parts with damp or wet hands Do not pull the power cable to disconnect it from the mains Verify that the machine is connected to the electrical outlet and that the outlet is connected to groun...

Страница 6: ...oning defective worn or broken parts must be replaced immediately for proper machine operation and for safety of personnel using the machine All changes and repairs must be performed by qualified pers...

Страница 7: ...r structures of the food improving taste and prolonging the shelf life in summary vacuum cooking allows us to obtain a tasty and fragrant dish without the addition of external condiments thereby guara...

Страница 8: ...quency which is contained on the machine identification label 6 2 Do not protect the machine with fuses of a greater value than the value indicated on the machine identification label 6 3 The product...

Страница 9: ...mer proceed as follows 1 Using the Timer dial set the cooking time value using the and keys press the OK key to save the data 2 Using the Tank Temperature dial set the maximum working temperature usin...

Страница 10: ...xxx on off enables or disables the temperature at the heart probe reading by Default it is enabled but it is automatically bypassed in the absence of the probe 6 Filter 50 60Hz important for greater r...

Страница 11: ...omatically light up to indicate the remaining time on cycle start up on expiry of the time it will automatically start based on the previously selected program Attention During the Auto Start timer se...

Страница 12: ...recipes a b and c and by the basic recipe with all the leds off for both the types of recipes To select a base recipe press the Recipes key The leds a b and c will illuminate in sequence following va...

Страница 13: ...t after about 2 minutes from the end of the pre registration 8 0 DEFAULT PARAMETERS SOUS COOKER has a table inside of factory preset parameters This table can be reloaded at any time and is particular...

Страница 14: ...Under no circumstances shall Elegen recognise complaints or compensation of or other nature 10 6 Elegen is equipped with product liability insurance for which damages recognised as eligible for compe...

Страница 15: ...s technical assistance network undertake to repair the product maximum in 90 days after the reception form the customer of the acceptance of reparation and according to availability of spare parts tha...

Страница 16: ...cted to the mains 2 check that the plug has been thoroughly inserted into the socket 3 check that the voltage current and frequency of the mains are consistent with data contained on the machine plate...

Отзывы: