7.2 WATER LEVEL CONTROL
The water level should be between the maximum and minimum level indicated on the frame of the machine, a lower level is not
accepted and the machine will block, for the low level.
7.3 HOLD FUNCTION
The Hold function is an innovative function to avoid proliferation of bacterial load on the product at the end of the cooking
cycle. At the end of cooking, if you do not intervene to switch off the SOUS COOKER within approx. 5 minutes from when the
cycle end warning is given, the control passes to the HOLD function and the temperature is automatically brought to 66°C, to
avoid proliferation of bacteria on the product.
This function is active by default, but you can disable it as you wish, to enable or disable the HOLD function, proceed as
follows:
1)
Press the Setting key
2)
The writing –HOLDFN ON- is displayed
3)
With the + and - keys of the probe dial at the heart select the desired option –HOLDFN ON- (enabled) HOLDFN OFF
(disabled)
4)
Press the OK key to confirm
Press the ESC key to exit the setting menu, or press the Setting key to continue with the settings.
7.4 SETTING KEY PROGRAMMING
You can program some parameters using the Setting menu, push
Setting
button to enter on it, every function is accessed by
pushing the button
The parameters that can vary are as follows:
1)
Preheating function programming: PrHEAT OFF. See dedicated section for setting 7.7
2)
Start the cycle in automatic Count Down mode;
Auto Start,
from this position you can program an end time based on
which SOUS COOKER starts the work cycle according to the previously selected program, you need to leave SOUS
COOKER switched ON.
3)
Limescale function (descaling), with this function it is activated the cleaning of the limestone that is deposited on resin
and on the immersed parts. To activate the function, press the button Place a sous cooker in a tank with water and
vinegar and start the decalcification function.
4)
Hold Function (HOLDFN xxx message); xxx = on- ; off ; enabled or disabled
HOLD
function (see paragraph relating
to this function section
7.3
), by default the function is enabled.
5)
Activation the probe at the heart (HEARTP xxx message); xxx = on- ; off; enables or disables the temperature at the
heart probe reading, by Default it is enabled, but it is automatically bypassed in the absence of the probe.
6)
Filter 50/60Hz, important for greater reading precision based on the mains frequency 50 / 60hz. (FILtEr xxx message):
xxx = 50H- ; 60H; Change filter trail activation at 50 and 60 Hz, by default 50Hz, in the zones where there is a mains
frequency of 60Hz, you should enable the filter at 60Hz for greater reading precision of the temperature.
7)
Reserved (COrreS xxx message); reserved parameter, use of this parameter is not recommended.
To access the setting of one of these parameters, Sous Cooker must be on the main mask.
1) Press the Setting key
2) The first parameter will be displayed
3) Press OK button to select the function with the Setting key and move to the next function,
This menu is sequential type and at the end of the selectable parameters it goes out and returns to the main mask.
Once the desired function has been selected to change a parameter, use the + and - keys of the dial for the parameter and
confirm with the OK key. To start the function, press the OK button.
Once the desired function has been selected to cancel it, press
STOP/START/ESC
until you return to the main screen.
When the Auto Start function is selected after a few minutes, a sequence of minus signs is displayed, the minus sign running on
the display and indicating the correct operation, a few minutes before the automatic switch on, the display is restarted and
indicating the remaining time at startup.
Attention!! in countries with a frequency of 60Hz, you need to set the parameter on FILtEr 60H, vice versa in countries
with a frequency of 50Hz, you need to set the parameter on FILtEr 50H (default value).
7.5 FN KEY SPECIAL FUNCTIONS ( only professional )
Pressing the FN key, you can access some special functions inside the system, pressing this key, the led lights up for the
fn on
key, to indicate the function is on. You can thereby access the following functions
1)
Displays the real temperature both of the tank and the probe at the heart, without heating;
LIVE
,
from this position, you can display the temperature both of the tank and the probe at the heart, to monitor the
temperatures.
2)
Adjustment of the circulator in manual mode without heating, with the real temperature display, both of the tank and
the probe at the heart;
CIRCULATOR
, from this position you can enable and display the temperatures both of the
tank and the probe at the heart, without heating being enabled.
You can vary the speed of the circulator to a desired
value between 5 and 10, 10 is the maximum value, 5 is the minimum value. In this function, it can be used as a simple