background image

INSTALLATION INSTRUCTIONS

20" (50.8 CM) FREESTANDING ELECTRIC RANGE 

with Standard Clean Oven

Table of Contents

RANGE SAFETY .............................................................................2

INSTALLATION REQUIREMENTS ................................................3

Tools and Parts ............................................................................3
Location Requirements ................................................................3
Electrical Requirements ...............................................................5

INSTALLATION INSTRUCTIONS ..................................................6

Unpack Range..............................................................................6

Install Anti-Tip Bracket.................................................................6
Electrical Connection ...................................................................7
Verify Anti-Tip Bracket Is Installed and Engaged ......................11
Level Range................................................................................12
Complete Installation .................................................................12

Check Operation ........................................................................12

W10459122A

IMPORTANT:

 

Save for local electrical inspector's use.

Содержание W10459122A

Страница 1: ...NTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti Tip Bracket 6 Electrical Connection 7 Verify Anti Tip Bracket Is Installed and Engaged 11 Level Range 12 Complete Installation 12 Check Operation 12 W10459122A IMPORTANT Save for local electrical inspector s use ...

Страница 2: ... the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not ...

Страница 3: ...dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See the Electrical Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 0 64 cm plywoo...

Страница 4: ...t less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 36 91 4 cm B 19 49 5 cm C 24 62 2 cm D 42 106 7 cm A B C D A 18 45 7 cm min clearance upper side cabinet to...

Страница 5: ...allic sheathed copper or aluminum cable See the Electrical Connection section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range 40 amps The w...

Страница 6: ...he anti tip bracket from where it is attached inside the oven with a wire tie 2 Determine which mounting method to use floor or wall If you have a stone or masonry floor you can use the wall mounting method If you are installing the range in a mobile home you must secure the range to the floor 3 Determine and mark centerline of the cutout space The mounting can be installed on either the left side...

Страница 7: ... and toward you to remove cover 3 Add strain relief Style 1 Power supply cord strain relief Assemble a UL listed strain relief in the opening Feed the power supply cord through the strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Rear position Front position Diagonal 2 options WARNING Electrical Shock Hazard Disconnect ...

Страница 8: ...od for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohibit grounding through the neutral 1 Part of metal ground strap must be cut out and removed A Large opening B Small opening A Small opening B Large opening A Small opening B Large opening A Removable retaining nut small opening B Conduit connector C Large opening A B A B A B A B C I...

Страница 9: ...his method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord 1 Feed the power supply cord through the strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 2 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 3 Co...

Страница 10: ...red wires Loosen do not remove the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs Securely tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart Bare Wire Torque Specifications Attaching terminal lugs to the terminal block 20 lbs in 2 3 N m 5 Use Phillips screwdriver to connect the bare green ground wire to...

Страница 11: ...d grasp the lower right or left side of the control panel as shown NOTE If your countertop is mounted with a backsplash it may be necessary to grasp the range higher than is shown in the illustration 2 Slowly attempt to tilt the range forward If you encounter immediate resistance the range foot is engaged in the anti tip bracket 3 If the rear of the range lifts more than 1 3 cm off the floor witho...

Страница 12: ...ction NOTE Range must be level for satisfactory baking performance CompleteInstallation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and wa...