background image

MANUAL CODE: XXXXX 

PROFESSIONAL SOUS COOKER 

 

ISSUE DATE: 15/01/2018  vers_00_05

 

Rev.  00.00   WITH REFERENCE TO FIRMWARE VERSION :00_15 and more  

 

 

ELE

GEN

 

by Quaglia Luigi  - Via Jmre Nagy  8-8/A 42019 - Scandiano Reggio Emilia Italy- VAT No. 02018620357 

TEL.+390522859721 – FAX +390522767677 - 

VOIP Skype. eleg2002 

- Web-www.elegen.it - emai

[email protected] 

 

 

Page  13  of 16 

 

with the probe at the heart or one or more steps with independently timed cooking. Simply using the relevant dial, the 
programs will also be maintained in the event of a power cut.

    

 

7.9 DISPLAYING CYCLE PARAMETERS    

 

It is possible to view the parameters of the cooking cycle, the maximum temperature, average temperature, the minimum 
temperature and the total time of the cooking cycle from when it turns on until the Sous Cooker goes off, the preheating cycle is 
excluded from the sampling, also the heating cycle is excluded from sampling, temperature values are considered only from 
when the temperature reaches the set point. 
At the end of the work cycle or during the work cycle it is possible to view the sampled parameters in the following way: 
              1) By pressing the OK key, the values will be scanned automatically or manually by pressing the OK key repeatedly. 
                  tEnp HI = maximum absolute temperature peak 
                  tEnp AU = average temperature of the cycle 
                  tEnp LO = minimum absolute temperature peak 
                  xx.xx tin tot _ total cycle timer (xx.xx = total cycle time) 
After pushing Ok button if the parameters are not displayed, wait several minutes and try again, infact some control filters are 
inserted to avoid incorrect sampling. 
The visualization of the cycle parameters at the end of a phase thermal sequence firing (TPS) will give the mean and maximum 
minimum values of the entire thermal sequence. 
If the preheating function is used, it may happen that the maximum temperature peak is much higher than the set point 
temperature. This depends on the speed with which the temperature decreases from the moment of insertion of the product in 
the tank. Sampling is carried out after about 2 minutes from the end of the pre-registration..   

 

8.0  DEFAULT PARAMETERS 

 

SOUS COOKER has a table inside of factory preset parameters. This table can be reloaded at any time   
and is particularly useful in the event of system malfunctions. In this case, you should simply reload the data to restore the 
system.  
To reload the default data, proceed as follows:  

1)

 

Switch off the SOUS COOKER on the main switch   

2)

 

Press the 

Setting

 key and keep it pressed 

3)

 

Switch on the

 SOUS COOKER on the main switch, keeping the 

Setting

 key pressed  

4)

 

Release the

 

Setting 

key as soon as the writing 

DEFAULT

 appears  

The factory data were reloaded, in this case, all the programmings implemented by the user were lost. 

 

 

8.1  HOUR AND CYCLE COUNTERS  

 

SOUS COOKER is equipped with a full hour counter or a cycles counter that keeps track of the actual working hours or the 
number of actual cycles. 
To display the hour counter and cycles counter  

 

 

1)

 

Switch off the SOUS COOKER on the main switch   

2)

 

Press the 

STOP/START/ESC 

key and keep it pressed 

3)

 

Switch on the SOUS COOKER on the main switch, keeping the 

T/t

 key pressed

  

 

4)

 

Release the 

STOP/START/ESC 

key,

 when the CYCLE 

xxxxxx message appears indicating the number of cycles

 

 

5)

 

To view the number of hours, press the 

OK

 key or wait a few seconds for the 

HOUR xxxxxx

 message 

to be automatically displayed.   

 

9.0  ALARMS   

 

SOUS COOKER is equipped with some controls to determine alarm situations for which the cycle is interrupted, when an 
alarm condition is created, the cycle is blocked and the type of alarm is indicated on the display which is generated, at the same 
time, the ALARM led is switched on, 
The alarms managed by SOUS COOKER are the following: 

1)

 

Water level alarm, immediate alarm message 

– no LEVEL –

 

2)

 

Main probe alarm, it is the probe inside the SOUS COOKER measuring the temperature of the tank. -

noPROBE1-

  

3)

 

No heating, if the temperature does not increase in value, -HEATING- 

4)

 

High temperature, if the temperature exceeds the 

HIGH TEMPERATURE

 set point temperature by some degrees   

5)

 

High temperature, at the heart of the product if the temperature at the heart of the product exceeds the 

HIGH HEART

 

set point temperature by some degrees   

To reset the alarm, press any key.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SOUS COOKER PRO CHEF

Страница 1: ...email elegen elegen it Page 1 of 16 Operating use and maintenance manual SOUS COOKER PRO CHEF SOUS COOKER PROFESSIONAL Low temperature immersion cooking system ATTENTION This manual contains all the...

Страница 2: ..._____________________________________ 7 5 0 DESCRIPTION OF THE CONTROL PANEL _______________________________________________________________ 8 6 0 INSTALLATION_________________________________________...

Страница 3: ...y law to diffuse or duplicate totally or partially the images and information contained in this manual without the manufacturer s prior authorisation The manufacturer is the owner of the rights to thi...

Страница 4: ...tly prohibited The fuse is a protection element that is essential to proper machine operation and in preventing damage to persons or property Always disconnect the mains before carrying out the operat...

Страница 5: ...machine parts with damp or wet hands Do not pull the power cable to disconnect it from the mains Verify that the machine is connected to the electrical outlet and that the outlet is connected to groun...

Страница 6: ...oning defective worn or broken parts must be replaced immediately for proper machine operation and for safety of personnel using the machine All changes and repairs must be performed by qualified pers...

Страница 7: ...r structures of the food improving taste and prolonging the shelf life in summary vacuum cooking allows us to obtain a tasty and fragrant dish without the addition of external condiments thereby guara...

Страница 8: ...quency which is contained on the machine identification label 6 2 Do not protect the machine with fuses of a greater value than the value indicated on the machine identification label 6 3 The product...

Страница 9: ...mer proceed as follows 1 Using the Timer dial set the cooking time value using the and keys press the OK key to save the data 2 Using the Tank Temperature dial set the maximum working temperature usin...

Страница 10: ...xxx on off enables or disables the temperature at the heart probe reading by Default it is enabled but it is automatically bypassed in the absence of the probe 6 Filter 50 60Hz important for greater r...

Страница 11: ...omatically light up to indicate the remaining time on cycle start up on expiry of the time it will automatically start based on the previously selected program Attention During the Auto Start timer se...

Страница 12: ...recipes a b and c and by the basic recipe with all the leds off for both the types of recipes To select a base recipe press the Recipes key The leds a b and c will illuminate in sequence following va...

Страница 13: ...t after about 2 minutes from the end of the pre registration 8 0 DEFAULT PARAMETERS SOUS COOKER has a table inside of factory preset parameters This table can be reloaded at any time and is particular...

Страница 14: ...Under no circumstances shall Elegen recognise complaints or compensation of or other nature 10 6 Elegen is equipped with product liability insurance for which damages recognised as eligible for compe...

Страница 15: ...s technical assistance network undertake to repair the product maximum in 90 days after the reception form the customer of the acceptance of reparation and according to availability of spare parts tha...

Страница 16: ...cted to the mains 2 check that the plug has been thoroughly inserted into the socket 3 check that the voltage current and frequency of the mains are consistent with data contained on the machine plate...

Отзывы: