background image

Lite

1

070-0630

Revision 7, December, 2000

© 2000, Electronics Diversified, Inc.

Lite

Control Console

with Soft-Patch

User Manual

Содержание Lite

Страница 1: ...Lite 1 070 0630 Revision 7 December 2000 2000 Electronics Diversified Inc Lite Control Console with Soft Patch User Manual ...

Страница 2: ...t patterns of light for special dramatic effects The Effects package is straight forward and user friendly for simple or complex application Finally the Lite Console is fast This means that when you touch the bump button you get an immediate response Meeting expectations is what makes the Lite Console simple We think that s the way it should be ABOUT THE LITE CONSOLE This User Manual is supplied w...

Страница 3: ...d LEDs 7 EFFECTS CONTROLS Program controls for Chase effects to include Mode direction and Page selections 8 PROGRAM KEY For recording Submaster memories For recording Effects memories For recording Soft Patch REAR PANEL 1 CONSOLE POWER MODULE On Off Switch Fuse Carrier 5 Amp Grounded recessed IEC connector for console power 2 DMX512 OUT Console output locking 5 pin XLR connector 3 ANALOG OUTPUT P...

Страница 4: ...buttons for direct output control of channels 3 ILLUMINATED CHANNEL LEDs Twelve 12 individual channel LEDs mimic the level output of the channel directed through the crossfader FADER Control console channels output through a split dipless crossfader between scenes 1 CROSS FADE TIMERS Sets fade time for associated faders 2 FADER 1 Controls levels set on channels in Scene 1 3 FADER 2 Controls levels...

Страница 5: ...p of channels with individual levels controlled as a group 1 SUBMASTER PAGE SWITCH The 3 position switch selects active memory page 2 SUBMASTER SLIDERS Six individual Pile on memory faders 3 SUBMASTER LED s Tri colored LED announces which memory page is active on the sider NOTE If the Submaster is empty LED will not light 4 SUBMASTER BUMP BUTTONS Six individual bump buttons for direct output contr...

Страница 6: ...d to program an Effect Rate and EM control playback of effect 1 MODE Activates Effect playback 2 DIRECTION Selects effect direction 3 PAGE Selects effect to be played 4 EFFECT RATE Selects the effect rate 5 STEP Displays the current step of the effect 6 EFFECT MASTER Controls effect output level 7 STEP HOLD Stops a running effect Steps a stopped effect Used when programming an effect 1 2 5 1 4 2 3...

Страница 7: ...LEVELS SET SCENE 1 LEVELS Selects Solo On Off bump functions SET SCENE 2 LEVELS Controls output level for bump functions PLAYBACK Playback each scene through the crossfaders SET FADE TIME Set Fader Time sliders to desired fader playback time ...

Страница 8: ...h will follow based on set Fader Time LED mimic lights will show levels set when a scene is active with Crossfader UP CROSSFADE Move both Faders together in the same direction One moves to 0 the other moves to 10 Bargraphs follow according to set fade time When the crossfade from Scene 1 to Scene 2 is complete the fader LED display in Scene 2 will be fully illuminated LED mimic lights will show ch...

Страница 9: ... BUMP OFF Bump buttons are deactivated on the console BUMP MASTER The Bump Master sets the output level for the channels bumped BUMP BUTTONS The buttons under the channel sliders allow the operator to force the channel output to the level selected on the Bump Master PLAYBACK HOLD THE BUMP The output level stays constant as long as you hold the button HINT If the channel level is at 25 and the Bump...

Страница 10: ...g as you hold the button HINT If the channel level is at 25 and the Bump Master is at FULL the bumped level is at 100 PRESS THE SUBMASTER BUMPS Submaster Bumps set the output level of all the channels stored in the Submaster to the level of the Bump Master OPERATION BUMP ...

Страница 11: ...bmaster bump PLAYBACK SUBMASTER OPERATION Select active Submaster page Move Submaster Slider to desired level Submaster outputs are controlled by the Grand Master Submasters operate on a highest takes precedence basis with the Crossfaders If the channel level is set higher on the manual output the Submaster output will not appear PRESS THE BUMP BUTTON Submaster output level will be controlled by t...

Страница 12: ...t the look for the first step of the effect The look may be any combination of console outputs to include channels submasters or combination outputs from the Crossfader 99 steps per Effect maximum P2 RECORDING AN EFFECT With the look output active press the STEP HOLD button to record the step The STEP display will indicate the step number recorded Select the next look for the 2nd step of the effec...

Страница 13: ...top a running effect OPERATION EFFECTS PLAYBACK Like Submasters Effects operate outside the Crossfaders Effects outputs are controlled by the Grand Master and the Blackout Switch USING THE EFFECT AS A SUBMASTER The effect package may be used as an additional timed submaster To use this function you must record an effect that is only one step long When the mode is set to RUN or STOP the effect may ...

Страница 14: ...ons will display the current channel assignment Press a different channel bump button to change the patch assignment or any Submaster bump to assign the dimmer to no channel Repeat for all desired dimmers Press the Program button when finished When in Patch Mode the analog outputs will mimic the channel bump LED s NOTE You cannot Patch Analog outputs TheSoft PatchallowsyoutoassignindividualDMX512d...

Страница 15: ... DISPLAY SHOWS CL The 7 segment step display window shows CL to alert operator that the console is in the erase memory mode PRESS THE STEP HOLD BUTTON This will erase all Submaster Effects memory RELEASE BOTH BUTTONS This will restore normal operation Step display window shows SOFTWARE VERSION On Power Up the Step display will show the version Number 3 0 3 0 CLEAR CL ...

Страница 16: ... The standard DMX 512 Data Cable is furnished with a 5 pin XLR style locking connector 25 in length Custom lengths are available on request ANALOG CONTROL CABLE The standard Analog Control Cable is furnished with a 25 pin D style connector with locking tabs 25 in length Custom lengths are available DMX REMOTE CONTROL UNIT Allows direct dimmer access for focus or dimmer checks without the control c...

Страница 17: ... connector 5XLR Output Pin Configuration 4 5 3 2 Lite consoles are available with two distinct types of dimmer address protocols identified as DMX 512 PROTOCOL DMX 512 is based on USITT standards Connector 5 pin XLR locking type Keyed connector style Upto512dimmeraddressedonasingleconnection All control pins are numbered See 5XLR pin detail illustration DMX 512 control is a digital signal transmit...

Страница 18: ... 123456789012345678901 123456789012345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1 B 2 3 1 2 E 4 F 5 12345678901234567890 12345678901234567890 12345678901234567890 12345678901234567890 12345678901234567890 DESCRIPTION EDI PART NUMBER 1 Power Connector on CPU card 2 DMX Output on CPU Card 3 Battery RAY O VAC BR2032 A CPU Board 670 8899 B F Channel Modules 670 8891 1 5 Addres...

Страница 19: ...GHTS Optional B DMX OUT POWER D D A E C ANALOG OUT Optional ANALOG OUT Optional DESCRIPTION EDI PART NUMBER A Power Switch 020 4001 B DMX Output 179 0501 C Houselights Optional D Analog Output Optional 020 4004 E Power Transformer 120 0070 ...

Страница 20: ...municate by FAX 1 503 629 9877 After Hours Emergency contact 1 503 645 5533 Ask for Emergency Assistance Internet www edionline com Internet E Mail service edi org This console is a product of 1675 N W Cornelius Pass Road Hillsboro Oregon 97124 USA If your Lite console needs repair call 503 645 5533 for a Return Materials Authorization number and a shippping address will be furnished ...

Страница 21: ..._____ Facility and or Company ________________________________________ _____________________________________________________________ Street Address _______________________________________________ _____________________________________________________________ City ____________________________ State ______ Zip __________ Phone ______________________________________________________ Fax _______________...

Отзывы: