Table E.1. 1:
Peak injector pulse widths for phase- and full-sequential injector firing. Injector
recovery time of zero is assumed.
RPM
Phase
Sequential
(1 inj. per rev.)
(ms)
Full
Sequential
(1 inj. per 2 rev.)
(ms)
0 - -
500 120.0 240.0
1000 60.0 120.0
1500 40.0 80.0
2000 30.0 60.0
2500 24.0 48.0
3000 20.0 40.0
3500 17.1 34.3
4000 15.0 30.0
4500 13.3 26.7
5000 12.0 24.0
5500 10.9 21.8
6000 10.0 20.0
6500 9.2 18.5
7000 8.6 17.1
7500 8.0 16.0
8000 7.5 15.0
8500 7.1 14.1
9000 6.7 13.3
9500 6.3 12.6
10000 6.0
12.0
10500 5.7
11.4
11000 5.5
10.9
11500 5.2
10.4
12000 5.0
10.0
12500 4.8
9.6
13000 4.6
9.2
13500 4.4
8.9
14000 4.3
8.6
14500 4.1
8.3
15000 4.0
8.0
15500 3.9
7.7
16000 3.8
7.5
16500 3.6
7.3
17000 3.5
7.1
17500 3.4
6.9
18000 3.3
6.7
18500 3.2
6.5
19000 3.2
6.3
19500 3.1
6.2
20000 3.0
6.0
______________________________________________________________________________________
TECgt Manual Version 2.0
- Page 78 -
©2008 Electromotive, Inc.