599 73 77-37
E69
E69: Washing heating element damaged
E69
Checks to perform:
Measure the resistance
value of the heating
element (
Ω
) between
terminals J3-1 ÷ J3-2 of the
wiring connector
-(see fig.4)-
Is the value correct?
(28÷31
Ω
for 230V/1,750W)
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Measure the resistance
value directly on the
terminals of the heating
element
(detach the connectors)
(see fig.20)
Is the value correct?
(28÷31
Ω
for 230V/1,750W)
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
NO
Y
E
S
NO
Y
E
S
MAIN CIRCUIT
BOARD
Washing heating element
28÷31
Ω
230V 1,750W
28÷31
Ω
230V 1,750W
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
J16 J1 J1
J10
J1
J4
J8
J7
J6
J1
J5
J3
J9
J1
Fig. 4