Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
68/75
599 73 77-37
Checks to perform:
Checks to perform:
Checks to perform:
EF6
EF6: Reset appliance.
EF6
EH1: Mains frequency incorrect
EH1
Power supply frequency out of configured range
EH1
EH2: Supply voltage too high
EH2
Supply voltage value higher than the one configured (for more than 10 seconds)
EH2
No action to be performed, if continues, replace the main circuit board.
Check that all the connectors are correctly inserted
!
Is the supply line disturbed or the mains
frequency out of range?
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarms.
Have the electrical system of the home
checked / repaired by the proper Body.
Is the supply line disturbed or the mains voltage
out of range?
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarms.
Have the electrical system of the home
checked / repaired by the proper Body.
Y
E
S
NO
NO
Y
E
S
Check that all the connectors are correctly inserted
!
Important
The appliance remains in alarm status until the mains frequency returns to the correct
values or the appliance is switched off (programme selector set to “0”). Only the family of
the alarm is displayed and the diagnostics mode cannot be accessed. The complete
alarm can only be read when the situation has normalised.
!
!
If there are burns on the circuit
board, see page 49
!
Important
The appliance remains in alarm status until the mains frequency returns to the correct
values or the appliance is switched off (programme selector set to “0”). Only the family of
the alarm is displayed and the diagnostics mode cannot be accessed. The complete
alarm can only be read when the situation has normalised.
!
!
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!