Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
29/75
599 73 77-37
Drain the water from the tub.
Are the pressure switch tube and
pressure chamber unobstructed?
(disconnect the tube and blow into it
to make sure the system is
unobstructed)
-(fig.2 and 8)-
E32
E32: The analogue pressure switch causes an error during calibration
(At the start of every cycle, the appliance drains to empty the tub and creates
a level 0 to check the calibration of the analogue pressure switch
E32
Checks to perform:
Clean/replace the tube and/or the
pressure chamber and repeat the
diagnostic cycle completely to check
for any further alarms.
Select a washing cycle. After a few minutes, has the appliance filled
with water and is the motor running?
Check the drain system (filter, drain
pump, drain tube). Is the appliance
draining correctly?
Repair
the drain
circuit.
Appliance ok.
NO
Y
E
S
NO
Y
E
S
Y
E
S
NO
Y
E
S
Fig. 2
Fig. 8
Replace the
analogue
pressure switch
and repeat the
diagnostic cycle
to check for any
further alarms.
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!