Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality tb
8/75
599 73 77-37
3.3 Diagnostic test phases
Irrespective of the type of electronic board and of the selector configuration, once the diagnostics system has
been activated, turn the selector dial
clockwise
to run a check of the various components and read the alarms
.
Concurrently, a selector control code is shown on the LCD display, which indicates for
two
seconds the
description in the last column of the table below. (all alarms are enabled in the diagnostic cycle).
TABLE 1
Selector
position
Components activated
Working conditions Function tested
LCD display
1
-
The LEDs, groups of symbols
in the LCD screen and the
backlight of the display are
turned on in sequence
-
Press a button/sensor to turn on
the group of icons in the LCD
screen or the corresponding
LED and the buzzer sounds at
the same time
Always active
User interface
functions
2
-
Door
safety
interlock
-
Wash
solenoid
Door closed
Water level below
anti-flooding level
Maximum time
5 mins
Water fill
to wash
compartment
Water level in
the tub (mm)
3
-
Door
safety
interlock
-
Pre-wash
solenoid
Door closed
Water level below
anti-flooding level
Maximum time
5 mins
Water fill
directly to tub
Water level in
the tub (mm)
4
-
Door
safety
interlock
-
Solenoid
valve
pre-wash and wash
Door closed
Water level below
anti-flooding level
Maximum time
5 mins
Water fill to
conditioner
compartment
Water level in
the tub (mm)
5
-
Door
safety
interlock
-
Third solenoid valve
Door closed
Water level below
anti-flooding level
Maximum time
5 mins
Water fill to
third solenoid
valve
compartment
Water level in
the tub is
displayed (mm)
6
-
Door
safety
interlock
-
Fourth solenoid valve (hot water
where featured)
Door closed
Water level below
anti-flooding level
Maximum time
5 mins
Water fill to
fourth solenoid
valve
compartment
Water level in
the tub is
displayed (mm)
7
-
Door
safety
interlock
-
Wash solenoid, if the water in
the tub is not enough to cover
the heating element
-
Heating
element
-
Weight sensor (an extra litre of
water is filled if featured)
Door closed
Water level above
the heating element.
Maximum time
10 mins or up to
90 °C
(*)
Heating
Temperature in
°C measured
using the NTC
probe