SOI/DT 2002-07 eb
20
599 35 36-69
5.5 Wool Cycles: cold - 30
°
- 40
°
Phase N. Function
Time /
control
Movement
Heat.
°
C
Notes
Delay
- Delayed start
Delay time
No Mov
Drain
0 Drain
VAE + 2”+
6” pause
No Mov
1 Wool water fill
P1 + Qwo (*)
2 Cold
wash
1’
Refill:P1+Qwo1
3 Heating
T
20/33/38
4 Maintenance
14’
Pwl_1
30-33 /
35-38
Wa
sh
5 Drain
VAE+14”
No
Mov
6 Water
fill
P1
No
Mov
7 Time water fill
Qwor1 (*)
8 Movement
3’
Refill:P1
1st
rinse
9 Drain
VAE+14”
Pwl_1
10 Water
fill
P1
No
Mov
11 Time water fill
Qwor1 (*)
12 Movement
3’
Pwl_1
Refill:P1
2nd
rinse
13 Drain
VAE+14”
No
Mov
14 Water fill
P1
No Mov
15 Movement
30”
16 Time water fill
Qwor2 (*)
17 Movement
5’
Pwl_1
Refill:P1
18 Drain
VAE+14”
No
Mov
R
in
s
es
Last rinse
(softener)
19 Drain + spin
3,5’
WOOL_CF
(max. 1000 rpm)
SW W1D00102
5.6 Hand wash Cycles: cold - 30
°
- 40
°
Phase N. Function
Time /
control
Movement
Heat.
°
C
Notes
Delay
- Delayed start
Delay time
No Mov
Drain
0 Drain
VAE + 2”+
6” pause
No Mov
1 Wool water fill
P1 + Qwh (*)
2 Cold
wash
1’
Refill:P1+Qwh1
3 Heating
T
20/33/38
4 Maintenance
14’
Pwl_4
30-33 /
35-38
Wa
sh
5 Drain
VAE+14”
No
Mov
6 Water
fill
P1
No
Mov
7 Time water fill
Qwor1 (*)
8 Movement
3’
Refill:P1
1st
rinse
9 Drain
VAE+14”
Pwl_4
10 Water
fill
P1
No
Mov
11 Time water fill
Qwor1 (*)
12 Movement
3’
Pwl_4
Refill:P1
2nd
rinse
13 Drain
VAE+14”
No
Mov
14 Water fill
P1
No Mov
15 Movement
30”
16 Time water fill
Qwor2 (*)
17 Movement
5’
Pwl_4
Refill:P1
18 Drain
VAE+14”
No
Mov
R
in
s
es
Last rinse
(softener)
19 Drain + spin
3,5’
WOOL_CF
(max. 1000 rpm)
SW W1D00102
Notes:
P1
time needed to 1
st
level water fill
(*)
time water fills are changeable and calculated by the electronic on the basis of the delivery rate
(see specific table)
T
time needed to heat the water at the set temperature
”
seconds
‘
minutes
VAE
time needed to drain the water till “empty” position of anti- boiling (safety heater) pressure
switch
Movement
: this column describes the drum movements at low speed and during spin (see paragraph “drum
movements”). The length of drain phases with spin cycle is approximate and does not take into
consideration the antiunbalance and antifoam safety systems.