SOI/DT 2002-07 eb
44
599 35 36-69
8.6 Table of alarm codes
Alarm
Description
Possible fault
Action/machine status
Reset
E11
Difficulties in water fill for washing
Tap closed or water pressure insufficient; drain hose incorrectly
positioned; water fill solenoid faulty; leaks from the hydraulic
circuit of the pressure switch; pressure switch faulty; wiring
faulty; PCB faulty.
Cycle paused
Start
E13
Water leakage
Drain hose incorrectly positioned; water pressure insufficient;
water fill solenoid faulty; leakage/blockage of pressure switch
hydraulic circuit; pressure switch faulty.
Cycle paused
Start
E21
Difficulties in draining
Drain hose kinked/blocked/incorrectly positioned; drain filter
blocked/dirty; drain pump faulty; pressure switch faulty; wiring
faulty; PCB faulty; current leakage from heating element to
ground.
Cycle paused
Start
E23
Drain pump triac faulty
Drain pump faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open
OFF
E24 Fault in “sensing” circuit of drain pump triac
PCB faulty.
Safety drain cycle – Cycle stopped
with door released
OFF
E33
Incongruence between closure of anti-boiling
and 1st level pressure switch contacts
Pressure switch faulty; current leakage from heating element to
ground; heating element; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open
OFF
E35
Water overflow (flooding)
Water fill solenoid faulty; leakage from pressure switch
hydraulic circuit; pressure switch faulty; wiring faulty; PCB
faulty.
Cycle blocked. Safety drain cycle.
Drain pump always in operation (5
minutes on, 5 minutes off etc.)
OFF
E36
Fault in “sensing” circuit of anti-boiling
pressure switch
PCB faulty.
Cycle blocked, door locked
OFF
E37
1st level sensing circuit faulty
PCB faulty.
Cycle blocked, door locked
OFF
E39
“HV” sensor of anti-overflow level faulty
PCB faulty.
Cycle blocked, door locked
OFF
E41 Door
open
Door interlock faulty; wiring faulty; PCB faulty.
Cycle paused
Start
E42
Problems of door closure
Door interlock faulty; wiring faulty; PCB faulty.
Cycle paused
Start
E43
Interlock power supply triac faulty
Door interlock faulty; wiring faulty; PCB faulty.
(Safety drain cycle) Cycle blocked
OFF
E44
Door interlock sensor faulty
PCB faulty.
(Safety drain cycle) Cycle blocked
OFF
E45
Door interlock sensing circuit triac faulty
PCB faulty.
(Safety drain cycle) Cycle blocked
OFF
E51
Motor power supply triac short-circuited
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts)
OFF
E52
No signal from motor tachometric generator
Motor faulty; wiring faulty; PCB faulty.
Cycle blocked, door locked (after 5
attempts)
OFF
E53
Motor triac sensing circuit faulty
PCB faulty.
Cycle blocked, door locked
OFF
E54
Motor relay contacts sticking
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts)
OFF