![Electrolux EWM1000 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/electrolux/ewm1000/ewm1000_service-manual_100453018.webp)
SOI/DT 2002-07 eb
18
599 35 36-69
5.3 Normal (consumer) Synthetics Cycles: cold - 30 - 40 - 50 - 60
°
(without options)
Phase N. Function
Time /
control
Movement
Heat.
°
C
Notes
Delay
- Delayed start
Delay time
No Mov
Drain
0 Drain
VAE + 2”+
6” pause
No Mov
1 Water fill
P1 + QPW1 (*)
2 Cold
wash
5’
D 55 from full
Refill:
P1
3 Water fill
QPW2 (*)
4 Heating
T
30 Cold = 20
°
C
5 Movement
5’
D 55
6 Drain
VAE + 15”
No Mov
7 Drain + spin
4,5’
C0
300/450/650 rpm
P
re-
w
a
sh
8 Drain
20”
No
Mov
9 Synthetics water fill
P1 + Qsy (*)
10 Cold
wash
10’
N 55 from full
Refill:
P1+Qy1
11 Heating
T
40
12 Movement
5’
Stains
13 “Stains” water fill
Qs (*)
N 55
Only with “Stains”
option
14 Heating
T
20/30/40/
50/60
Economy = 42
°
C
15 Movement
10’
N55 with T
>
40
°
E55 with T
≤
40
°
16 Heating
T
20/30/40/
50/60 Economy = 42
°
C
17 Movement
15’
E55
Economy
=
25’
18 Cooling water fill
Qc (*)
Cooling
19 Movement
1’
N55
20 Drain
VAE
No
Mov
Wa
sh
21 Drain
1’
D55
22 Water fill
P1+ Qyr1 (*)
23 Movement
3’
E55 from full
Refill:
P1
24 Drain
VAE
No
Mov
1st
rinse
25 Drain
1’
D55
26 Water fill
P1+ Qyr2 (*)
27 Movement
3’
E 55 from full
Refill:
P1
28 Drain
VAE
No
Mov
29 Drain
1’
D55
2nd
rinse
30 Drain + spin
4’
C0
300/450/650 rpm
31 Water fill
P1
32 Movement
30”
33 Time
water
fill
Qyr3
34 Movement
5’
E55 from full
Refill:
P1
35 Drain
VAE + 14”
No Mov
36 Drain + spin
4,5’
SYN_CF
(max. 900 rpm)
R
in
s
es
Last rinse
(softener)
37 Untangling
1’
N55
Not
for
Economy
SW W1D00102
Notes:
P1
time needed to 1
st
level water fill
(*)
time water fills are changeable and calculated by the electronic on the basis of the delivery rate
(see specific table)
T
time needed to heat the water at the set temperature
”
seconds
‘
minutes
VAE
time needed to drain the water till “empty” position of anti- boiling (safety heater) pressure
switch
Movement
: this column describes the drum movements at low speed and during spin (see paragraph “drum
movements”). The length of drain phases with spin cycle is approximate and does not take into
consideration the antiunbalance and antifoam safety systems.