Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.50/88
LS6AH
Prog. 027
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading door type.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
RE
0
Regeneration cycle disabled.
ALr 1
ALARMS ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt°C 84
Boiler Temperature Threshold.
bAJ 0
Boiler Temperature Adjust.
btd 3
During stand-by boiler is kept at lower temperature than Temperature Threshold.
tt°C 68
Tank Temperature Threshold.
ttH 2
HISTERESIS of Tank Temperature.
5.
Modify the cycle parameters:
CY1
Cycle 1 parameters family.
Ln1
1
Long Wash Phase [min]
Sh1 36
Short Wash Phase [s]
FP1 4
Final Pause [s]
CY2
Cycle 2 parameters family.
Ln2
2
Long Wash Phase [min]
Sh2 36
Short Wash Phase [s]
FP2 4
Final Pause [s]
CY3
Cycle 3 parameters family.
Ln3
3
Long Wash Phase [min]
Sh3 36
Short Wash Phase [s]
FP3 4
Final Pause [s]
dPA
Set other parameters.
C F
1
Fahrenheit.
6.
Switch OFF and then switch ON the machine.