ECOTEMP 5
Prog. 016
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 0
Tank and boiler heaters work simultaneously.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI 8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE 0
Regeneration cycle disabled.
ALr 1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt°C 77
Boiler Temperature Threshold.
btd 3
During stand-by boiler is kept at lower temperature than Temperature Threshold.
5.
Modify the cycle parameters:
CY1
Cycle 1 parameters family.
Ln1
1
Long Wash Phase [min]
Sh1
10
Short Wash Phase [s]
ri1
25
Rinse Phase Duration [s]
dr1
40
Drain [s]
FP1 4
Final Pause [s]
CY2
Cycle 2 parameters family.
Ln2
2
Long Wash Phase [min]
Sh2
22
Short Wash Phase [s]
ri2
25
Rinse Phase Duration [s]
dr2
40
Drain [s]
FP2 4
Final Pause [s]
CY3
Cycle 3 parameters family.
Ln3
4
Long Wash Phase [min]
Sh3
22
Short Wash Phase [s]
ri3
25
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3 4
Final Pause [s]
drn
Drain parameters family.
Idr
30
Initial Drain Phase Duration [s]
dPA
Set other parameters.
IPA
5
Initial Pause [s]
6.
Switch OFF and then switch ON the machine.