Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.16/88
AAG
Air gap with float level sensor.
-
0
1
0
dbG
Parameters for automatic hood type dishwashers
Sym. Parameter
Description
Unit Min Max
Factory
Default
t 1
DELAY_K1
Time (during hood lifting) within which S3” must return to the rest position.
0.1 s
0.0 s.
20.0 s
15
t 2
HOOD_TOUT
TIMEOUT – max. time allowed for complete hood opening/closing.
0.1 s
0.0 s.
20.0 s
200
t 3
DELAY_K1_S3
During hood lowering, firstly S3” must cut in and then after a time
t3 .
the bottom limit switch S3.
0.1 s
0.0 s.
20.0 s
15
t 4
DELAY_K
Time within which K and K’ must be both closed or both open.
0.1 s
0.0 s.
20.0 s
10
t 5
DELAY_S3
Time during hood lifting within which the bottom limit switch must return
to the rest position..
0.1 s
0.0 s.
20.0 s
20
t 6
DELAY_S5
Time during hood lowering within which the top limit switch must return to
the rest position.
0.1 s
0.0 s.
20.0 s
20
AL_
Displays the last alarm code relative to automatic hood type dishwashers.
-
-
-
-
Ith
Parameter only valid for hood type models.
Hood lifting motor absorption threshold.
(50 units correspond to a current of approx. 1 ampere).
- 0 250
100
sEN
Parameter for the implementation of new characteristics [present up to
software version 3.12].
- 0 1
0