P.15/88
Prn
Print parameter table.
-
0
1
1
bt
HACCP ‘Basic’ (printer)
Boiler temperature: high limit.
[°C] 45 95
90
bH
HACCP ‘Basic’ (printer)
Boiler temperature: gap below high limit.
[°C] 0 20
10
tt
HACCP ‘Basic’ (printer)
Tank temperature: high limit.
[°C] 35 75
68
tH
HACCP ‘Basic’ (printer)
Tank temperature: gap below high limit.
[°C] 0 20
10
CFG
Configuration
Parameters
Sym. Parameter
Description
Unit Min Max
Factory
Default
tYP
Dishwasher Model:
0 = HOOD TYPE & UNDERCOUNTER
1 = POT WASHER
2 = AUTOMATIC POT WASHER
3 = MEDICAL LINE DISHWASHER WITH LOCK DOOR/HOOD
DEVICE
- 0 3
0
boi
Boiler type:
0 = ATMOSPHERIC BOILER
1 = PRESSURE BOILER
2 = EXTERNAL BOILER
- 0 2
0
doo
Door type:
0 = AUTOMATIC HOOD
1 = MANUAL HOOD
2 = FRONT LOADING
3 = POT WASHER
0 3
1
dFL
Default model (see
Default tables
):
1 = HOOD TYPE
2 = POT WASHER
3 = UNDERCOUNTER
- 0 3
-
trc
Solid State Relay (TRIAC).
0 = not enabled;
1 =
SOFT START
enabled;
3 =
SLOW SOFT START
enabled
(works only on boards with Solid State Relay).
- 0 3
0
b_t
Boiler/Tank heating swap:
0 =
boiler heaters and tank heater can work simultaneously;
1 =
swap enabled: tank heating starts only boiler temperature is
reached;
(Note: disabling this function changes the global electrical power of
appliance; before enabling this function check available power, supply cable
section, fuses in according to User Manual).
- 0 1
1
btF
Tank Filling Mode
Enable filling tank by means of rinsing cycles.
Ex:
btF
= 75 means that boiler water is heated at 75°C, then follows a
rinse phase and so on until tank is full.
If
btF
= 0 the tank is filled by solenoid valve in the traditional way.
[°C] 0 85
75
LES
Detergent Level Switches
0 =
level switches not enabled;
1 =
enable detergent level switches;
- 0 1
0
UI
USER INTERFACE MODEL
8
= ACTIVE function disabled
(up to version 3.11 [up to serial nr.
42100099] set to 0)
9 =
hood type, under counter
(up to version 3.11 [up to serial nr.
42100099] set to 1)
13 =
LS5 with atmospheric boiler
(up to version 3.11 [up to serial nr.
42100099] set to 5)
15 =
LS5 with pressure boiler (user interface without display);
(up to
version 3.11 [up to serial nr. 42100099] set to 7)
See parameter
rEL
(family
ron
)
to check the software version
installed in the board.
- 0 15
9
r
E
Enable “regeneration cycle” key (only for dishwashers with non-continuous
water softener) [See paragraph 9.1 resin regeneration cycle].
- 0 1
0
ALr
ALARMS ENABLE
0 =
alarms disabled (to disable also warnings see
bLo
and
tLo
);
1 =
alarms enabled;
If this function is disabled, faults can be detected so display do not shows
any alarm code.
- 0 1
1