Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.49/88
LS12 ECOTEMP UK
Prog. 026
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 1
Manual Hood.
dFL 1
Default values for Hood Type models.
trc 0
(for this appliance SOFT START is NOT possible).
b_t 1
Tank heater works only if boiler temperature reached.
btF 0
The tank is filled into the traditional way.
LES 0
Detergent level switches not enabled.
UI 9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
RE 0
Regeneration cycle disabled.
ALr 1
ALARMS ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt°C 82
Boiler Temperature Threshold.
bAJ 0
Boiler Temperature Adjust.
5.
Modify the cycle parameters:
CY1
Cycle 1 parameters family.
DR1
0
Drain [s]
CY2
Cycle 2 parameters family.
DR2
0
Drain [s]
CY3
Cycle 3 parameters family.
DR3
0
Drain [s]
drn
Drain parameters family.
Idr
30
Initial Drain Phase Duration [s]
dPA
Set other parameters.
Pdr
30
Drain Phase Duration at the end of washing phase. [s]
6.
Switch OFF and then switch ON the machine.