P.46/88
LB5G/WT4G Prog.
022
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading door type.
dFL 3
Default values for Undercounter models.
trc 0
(for this appliance SOFT START is NOT possible).
b_t 1
Tank heater works only if boiler temperature reached.
btF 0
The tank is filled into the traditional way.
LES 0
Detergent level switches not enabled.
UI 15
Select user interface for LS5
(up to version 3.11 set to
7
)
.
rE 0
Regeneration cycle disabled.
ALr 1
ALARMS ENABLED.
3.
Switch OFF and then switch ON the machine.
4.
Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt°C 85
Boiler Temperature Threshold.
bAJ 0
Boiler Temperature Adjust.
bSt 2
Booster Function.
5.
Modify the cycle parameters:
CY3
Cycle 3 parameters family.
Ln3
1
Long Wash Phase [min]
Sh3 40
Short Wash Phase [s]
6.
Switch OFF and then switch ON the machine.
7.
Modify Detergent dosage:
GEn
Enter into GEn parameter family.
dIn 70
Initial Detergent Dosage [s].
rIn 5
Initial Rinse Aid Dosage [s].
8.
Switch OFF and then switch ON the machine.
ECOTEMP5 EAG
Prog. 023
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading door type.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.