![Electrolux Diva EDW 2000 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/electrolux/diva-edw-2000/diva-edw-2000_service-manual_91966004.webp)
- 4 -
09.2002 R.K.
3. Components
3.1 Electronic
On electronic models, a micro processor controls all
components, this is done using triacs. The electronic also
memorizes all programme data.
Die Steuerelektronik besteht aus dem (1) Eingabe-, (2) Ausga-
be- und (3) Steuerteil.
1
2
3
3.2 Circulation Pump
The circulation pump is driven by an asynchronous motor with
an auxiliary winding. The auxiliary winding ist in circuit with a 3
mF capacitor. A tacho generator is used for speed control.
There are three speeds for rinsing.
2800 1/min, 2200 1/min, 1900 1/min, 1700 1/min, 1600 1/min,
Power output 50 W.
3.3 Drain Pump
The drain pump is driven by a synchronous motor.
Power output 26 W.
Pump rate 15 l/min.
3.4 Flow Heater
The flow heater heats the water to the required temperature.
During the wash cycle, water is contantly passing through the
flow heater.
Power output
2000 W
Resistor
25
W
Protector
98 °C ± 5 K
Thermal fuse
260 °C
Only for models with ceiling Sprayarm