![Electrolux Diva EDW 2000 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/electrolux/diva-edw-2000/diva-edw-2000_service-manual_91966039.webp)
6.16. Service function / manufacturing test routine:
General information
Calling above-mentioned service function
w
Calling the service functions is executed in all designs
Calling the function "manufacturing test routine"
resp. key arrangements analogously.
w
For that you always have to use keys S1, S2, S3 and S4
1.
Press keys S2 and S4 simultaneously and ...
independent of their variant-depending program load.
w
In the service function mode, key S4 is ALWAYS
2.
... and switch on the appliance with ON/OFF switch S1.
responsible for calling the "manufacturing test routine"
For that keep the keys S2 and S4 pressed simultaneously
until the 3 confirmation LEDs LD2, LD3 and LD4 are flashing.
(about 4 seconds) The LD1 display with ON/OFF key is lit.
(A temporary flashing up of LEDs is possible and no fault!)
3.
By actuating the function key S4 you now can call the
manufacturing test routine. The confirmation LED LD4 is
flashing and the ON/OFF LED continues to be lit, LEDs
LD2 and LD3 go out.
4.
The test routine starts automatically.
Following displays are available depending on the variant of
equipment.
The run time LED is flashing up.
The display indicates the presumable run time.
The corresponding PAA LEDs are lit.
From that moment the same input philosophy is valid for the manu-
facturing test routine as for normal washing cycles, but the program
LED LD4 is flashing until the end of the manufacturing test routine.
F
cycle run and cycle end
(see description page B 5 )
Always applicable:
F
delete cycle in advance
In order to call the totality of service functions always first
(see description page B 6 )
press the function keys S2 and S4 prior to switching the
F
interrupt program
appliance on by means of ON/OFF switch S1!
(see description page B 8 )
Keep the keys pressed for abt. 4 seconds in order to
activate the function. This procedure is intentionally
distinguished from those for the customer functions.
ATTENTION:
In case of reduced key assemblies be sure
to observe Description Page B 1.
S1
On/Off
LD1
S2
LD2
LD3
S3
S4
LD4
S1
On/Off
LD1
S2
LD2
S3
LD3
S4
LD4
1.99
1.99
vertical key arrangement
horizontal key arrangement
S1
On/Off
LD1
LD2
LD3
LD4
1.
2.
S1
On/Off
LD1
S2
LD2
LD3
S3
S4
LD4
S1
On/Off
LD1
S2
LD2
LD3
S3
LD4
3.
S4
LD1 is lit / LD2 - LD4 flashing
LD1 is lit / LD4 flashing
S2
S3
S4
S1
On/Off
LD1
S2
LD2
LD3
S3
LD4
21
4.
S4
LD1 is lit / LD4 flashing
manufacturing test routine running.
Prog.time
PAA